Laserfiche WebLink
personnel. The certified applicator supervising the application must ensure the FMP is at the <br />applicatfon.block during all handier activities. <br />Within 30 days after the application is complete, the certified applicator supervising the <br />application must complete a Post Application Summary. <br />POST -APPLICATION SUMMARY <br />The Post-Appilcatlon Summary must contain the following elements: <br />• Actual date and time' of the application, <br />• Applicationrate, <br />• Size of appplication block. <br />• Weather Condifions <br />o Summary of the National Weather Service weather forecast during the application and <br />the 46 hours after the application is complete including: <br />o wind speed, and <br />o air stagnation advisory (if applicable) <br />o Forecast must be checked on the day of, but prior to the start of the application, and on <br />a dally basis during the application if the time period from the start of the application <br />until the application is complete is greater than 24 hours. <br />• Tarp damage and repair information (if applicable) <br />o Date of tarp damage discovery, <br />o Location and size of tarp damage, <br />o Description of tarp/tarp sekl/tarp equipment failure, and <br />o Date and time of tarp repair completion. <br />• Tarp perforation/removal details (if applicable) <br />0 Data and time tarps were perforated, <br />o Date and lime tarps were removed, and <br />o Record if tarps were perforated and/or removed eady: Describe the conditions that <br />caused early tarp perforation and/or removal <br />• Complaint details (f applicable) <br />0 Person filing complaint (e.g., on-site handler, person off-site), <br />o If off-site person, name, address, and phone number of person filing complaint, and <br />P Description of control measures or emergency procedures followed after complaint <br />• Description,of incidents (including date and time), equipment failure, or other emergency <br />and emergency procedures followed (If applicable). <br />• Communication between applicator, owner and other on-site handlers (f applicable) <br />Q Record additional dates persons were contacted <br />• Air monitoring. results: <br />o Date(s), time(s) and locations) of sensory irritation or air sample measurement with the <br />direct read detection device, <br />o Handier name and task/activity <br />o Air concentration measurement with direct read detection device (if applicable) <br />0 Resulting action/comments (e.g,, cease operations, continue operations with air - <br />purifying respirators, implement emergency response plan) <br />• Water -run application monitoring <br />o Record monitoring date(s) and time(s) <br />0 Name ofppersons) monitoring <br />o Record gbservatlons: <br />— Is.the equipment functioning properly, <br />— Description of corrective action (if applicable), and <br />— Othercomments <br />• Fumigant Treated Area andBufferZone.Signs <br />o Dates of posting and removal <br />• Any deviations from the FMP (e.g,, changes In emergency response actions; changes.in <br />handier information, changes in handlers responsible for. completing emergency tasks). <br />Record -Keeping Procedures <br />The owner of the application block as well as the certified applicator supervising the <br />dapli a ionappcuss keep a signed copy. of the Post -Application Summary for 2 years from the <br />PRODUCT INSTRUCTIONS <br />Sectagon 42 is a water-soluble liquid. When applied to properly prepared soil, the liquid <br />is converted into a gaseous fumigant. After a sufficient waitingpperiod, the gas dissipates, <br />leaving the soil ready for planting, Sectagon 42 is regommended for the suppression of <br />weeds, plant parasitic nematodes, and soilborne fungi that cause reductions in the yield and <br />quality of ornamental, food and fiber crops. <br />Sectagon 42 will suppress only those pests in the fumigation zone at the. time of treatment <br />Recontamination may occur subsequent to the fumigant's dissipation from the soil. <br />Weeds and germinating weed seeds thatare suppressed include Annual bluegrass, Bermuda <br />grass, Chickweed, Dandelion, Ragweed, Henbit, Lambsquarter, Amaranthus. sp, (Pigweed, <br />Careless weed), Watergrass, Johnsongrass, Nutgrass, Wild momingglory, Purslane, <br />Barnyardgrass, Crabgrass, Groundsel, Prickly lettuce, Pineappleweed, Nettieaf, Goosefoot, <br />Nightshade, Shepherdspurse, Stinging nettle, Melva, London rocket, and Fiddleneck. The <br />best weed suppression is obtained when Sectagon 42 is applled to weeds that are actively <br />growing, <br />Sectagon42 20131ndd 27 <br />Al1C U2 1. 2 015 <br />t m � � � s 5 �' * r� •.5 F �� S I <br />The soll-bome plant pathogenic -fungi suppressed include species of Verticillium, Rhizactonia, <br />Pythium; Phytophthora, Sclerotinia. <br />The plant parasitic nematodes which Sectagon 42 suppressed include Root knot, Lesion, <br />Dagger, Lance, Needle, Pin, Reniform, Stunt, Stubby root, Sting and Spiral. <br />Note: Sectagon 42 will only suppress nematodes that are. in thefumigated zone at the time <br />of treatment. The fumigated zone is defined as the depth of penetration that Sectagon 42 <br />achieves atthe time of application. In Oregon.and Washington, Sectagon 42 will only suppress <br />Miloidogyne Chitwoodi. Other pests suppressed include symphillds or garden centipedes. <br />USE PRECAUTIONS <br />Keep off desirable lawns and plants. <br />USE RESTRICTIONS <br />Do not apply within 3 feet of the drip line of desirable plants, shrubs or trees. Do not use in <br />confined areas without adequate ventilation OR where fumes may enter nearby dwellings. <br />Do not use in greenhouses. Keep container tightly closed when not In use, Oo not store near <br />feed or food. <br />TREATMENT GUIDELINES <br />For optimum results from soil fumigation with Sectagon 42 certain procedures should <br />be observed at designated times In the treatment program. Described in this: section are <br />important guldelines.for each of the four stages of the treatment process: <br />Planning a Sectagon 42 Application <br />Preparing a Fleldfor Application <br />Applying Sectagon 42 <br />Preparing for Planting after Application ofSectagon 42 <br />Your sales representative will help you select the besttreatment program for your particular <br />needs. <br />PLANNING A SECTAGON 42 APPLICATION <br />Time. of Application <br />Apply Sectagon 42 after harvest and 14 to 21 days before a new crop is planted. in some <br />areas of North America, fall applications are preferred because the fumes dissipate over the <br />winter, allowing planting to begin as soon as favorable springtime conditions arrive. <br />Application Hate <br />Apply 37:5 to 75 gallons of Sectagon 42 per treated acre depending on crop, target pest, and. <br />soil properties. Sall properties to consider when: determining the,appiication rate include the <br />depth. of soil to be treated, soil texture and percent organic matter. <br />Application in Tank Mix with Liquid Fertilizer <br />Sectagon 42 may be injected In a mixture with liquid fertilizers. Since the composition of liquid <br />fertilizers vary considerably, the physical compatibility of each fertilizer/Sectagon 42tank mix <br />should be checked by using the following procedure: <br />Mix a small quantity of Sectagon 42 and liquid fertilizer in a glass container. Sectagon 42 and <br />fertilizer should be mixed In the same ratio as they will be applied to the field (Le., if 40 gallons <br />of Sectagon 42 and 49gallons of liquid fertilizerare to be applied per acre; then Sectagon <br />42 and fertilizer should be mixed in the jar in a.40:40 or 1:1 ratio). Agitate the liqulds to attain <br />a.complete mixture: <br />If a uniform mix cannot be made, the mixture should not he used. If the mixture remains <br />uniform for30 minutes, the combination may be used. Should the mixture separate after 30 <br />minutes, but readily remixes uniformly with agitation, the mixture can be used if adequate <br />agitation is maintained in the tank, <br />DO NOT PLACE CAPS ON JAR, AS INCOMPATIBLE MIXES MAY EVOLVE HYDROGEN <br />SULFIDE GAS. <br />USE PROMPTLY AFTER MIXING WITH WATER OR FERTILIZER. DO NOT ALLOW SOLUTION <br />TO STAND. <br />Flush all equipment with water after each day's use. Disassemble valves and clean carefully. <br />All rinsate should be properly applied to the field. <br />Target Pest and Depth of Treatment <br />For suppression of weeds and fungi causing seed or seedling diseases, treatment of only <br />the top'1 to 4 inches of, soil may be required (see application specific requirements in the <br />.Good Agricultural Practices section of thisiabel). For suppression of nematodes and fungi <br />which occur throughout the rhizosphere, treatment to depths of greater than 4 inches may be <br />required. For a given soil type, the required application rate within the specified rate range <br />will Increase proportionately up to the specified maximum rate with the depth of treatment <br />required. <br />For example, if 25'gallons of Sectagon 42 per acre is required to treat 4 inches, then 50 <br />gallons of Sectagon 42 will be required to treat to a depth of B inches. Choose the appropriate <br />0 <br />6111/2015 10:25:56 AM <br />