My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1553
>
2300 - Underground Storage Tank Program
>
PR0516526
>
COMPLIANCE INFO 2007-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2019 4:45:49 PM
Creation date
11/1/2018 10:33:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 2007-2011
FileName_PostFix
2007-2011
RECORD_ID
PR0516526
PE
2361
FACILITY_ID
FA0012659
FACILITY_NAME
LOVE'S COUNTRY STORES OF CALIF #223
STREET_NUMBER
1553
STREET_NAME
COLONY
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
24534024
CURRENT_STATUS
01
SITE_LOCATION
1553 COLONY RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
194
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S WRCB,January 2002 <br /> Page o <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps <br /> Fill Riser Containment Sumps are Present,but were Not Tested <br /> Test Method Developed By: D Sump Manufacturer i=i Industry Standard X Professional Engineer <br /> i <br /> :.:.!Other(Spec) <br /> 'rest Method Used: ❑Pressure ❑Vacuum X Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: Caldwell Level Change Indicator Equipment Resolution: 002 <br /> Fill Sump#5-US Fill Sump# Fill Sump # Fill dump #Y <br /> Sum Diameter: 42" <br /> Sump Depth: 74" _ <br /> Height from Tank Top to Top of 19 ''/s" <br /> Highest Pip ng Penetration: —� <br /> Height from Tank Top to Lowest 38 <br /> Electrical Penetration: <br /> Condition of sump prior to Dry <br /> testing: <br /> Portion of Sump Tested Water Line 43 '/z" <br /> 4r Sump Material: Fiberglass <br /> Wait time between applying 5 Minutes <br /> water and startingtest:st: <br /> Test Start Time: 11:15 <br /> Initial Reading(Rj): .001 —..._ <br /> Test End Time: 11:45 <br /> h <br /> Final Reading(RF)' .001 ; <br /> Test Duration: 30 Minutes <br /> Change in Readin (RF-Ri): 0 <br /> Pass/Fail Threshold or Criteria: .005/30 Minutes <br /> Test Result. X Pass ❑Fail Pass ❑Fail Pass ❑Fail ❑ Pass ❑Fail <br /> a <br /> Is there a sensor in the sump? X Yes [.:J No Yes ❑No Yes ❑No Yes ❑No ' <br /> Does the sensor alarm when <br /> either product or water is X Yes 0 No ❑NA Yes ❑No ❑NA Yes ❑No ❑NA Yes D No ❑NA <br /> detected? — <br /> Was sensor removed for testing? X Yes No ❑NA Yes ❑No ❑NA Yes No NA Yes ❑No L_:NA <br /> Was sensor properly replaced and <br /> verified functional after testin ? X Yes O No F NA I Yes ❑No ❑NA Yes No NA Yes 0N ::...NA 53 <br /> Comments—(include information on repairs made prior to leslin , crud recommended follow-up for ailed tests <br /> rdge to ui Li <br />
The URL can be used to link to this page
Your browser does not support the video tag.