My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KASSON
>
25001
>
2200 - Hazardous Waste Program
>
PR0538492
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2021 10:22:00 AM
Creation date
11/1/2018 10:51:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO_PRE 2019
FileName_PostFix
PRE 2019
RECORD_ID
PR0538492
PE
2220
FACILITY_ID
FA0015498
FACILITY_NAME
Skydive California, LLC
STREET_NUMBER
25001
STREET_NAME
KASSON
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
23918005
CURRENT_STATUS
02
SITE_LOCATION
25001 KASSON RD
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\K\KASSON\25001\PR0538492\COMPLIANCE INFO 2014 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2014 - 2015
QuestysRecordDate
10/19/2017 8:45:17 PM
QuestysRecordID
2936908
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sogov.org/ehd <br /> CONTINUATION FORM Page: 7 of 7 <br /> OFFICIAL INSPECTION REPORT Date: 05/05/14 <br /> Facility Address: Trinkle Ag Flying Inc 25001 Kasson Road, Tracy Program: HW <br /> SUMMARY OF VIOLATIONS <br /> CLASS I, CLASS II,or MINOR-Notice to Comply) <br /> 9999. HSC 66262.34(d)(2), refer to 40CFR 265.35 via 262.34(d)(4). Failed to maintain enough room for <br /> unimpeded access to containers. The two drums of used oil and three drums of oily-water do not allow <br /> sufficient space to walk or squeeze through as they are situated between two large sheds. There are <br /> several smaller containers and buckets located behind these drums which are difficult to access to <br /> determine if there is other storage of hazardous substances. Drums are impeding access to clean up <br /> spilled waste. <br /> -Facility shall maintain aisle space to allow the unobstructed movement of personnel, fire, protection <br /> equipment, spill control equipment, and decontamination equipment to any area of facility operations in <br /> an emergency. <br /> -Immediately correct by maintaining aisle space to allow movement through the area. <br /> 9999. HSC 25404(e)(4). Failed to submit business program data electronically. <br /> -Information submitted to the statewide information management system CERS shall include, but not be <br /> limited to, hazardous material inventory, hazardous waste, above ground storage tanks, emergency <br /> response plans, and site map. <br /> -Immediately correct by logging into CERS and submitting all hazardous material data required. <br /> Submit to the EHD by June 30, 2014: <br /> 1. one copy of the completed "Return to Compliance Certification" form <br /> 2. a written corrective action statement for each of the above violations <br /> 3. copy of requested/ supporting documentations <br /> Notes: <br /> -Facility has an aboveground storage tank for gasoline. Appears to be approx 2,000 gallons capacity. <br /> -Request to take photographs was refused. <br /> -Request for signing inspection reports was refused. Sending report certified mail as requested by <br /> owner. <br /> Inspection incomplete. Did not go to shop or anywhere else on property except the used oil storage <br /> area. Did not review any records, contingency plans, SPCC Plans. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Inspector. Received By: Title: <br /> Thuy Tran (209) 468-8257 Sent by Certified Mail <br /> EHD 23-02-003 Rev 04/19/12 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.