Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax: (209)468-3433 Web:www.sigov.org/ehd <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> INTERSTATE TRUCK CNTR 825 NAVY DR STOCKTON June 26 2015 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 502 CCR 66265.192(k) Hazardous waste tank assessment is incomplete. <br /> The hazardous waste tank assessment for the used antifreeze tank is incomplete. The tank assessment did not <br /> include tank configuration, hazardous characteristics of the waste being stored, estimated remaining service life, <br /> material thickness and the method used to determine the thickness, and a sketch or drawing of the tank with <br /> dimensions. The tank assessment stated that"the exterior surface coating (paint) on the tank requires maintenance," <br /> that the"tank should be secured to prevent movement,"and that"safety bollards placed in strategic locations to <br /> protect from trucks/vehicles." The hazardous waste tank assessment shall include all of the following information: <br /> 1. tank configuration (i.e., horizontal, vertical), material of construction, and gross capacity (in gallons); <br /> 2. design standard(s), if available, according to which the tank and ancillary equipment were or will be constructed <br /> and all of the following information: <br /> A material of construction; <br /> B. material thickness and the method used to determine the thickness; <br /> C. description of tank system piping (material, diameter); <br /> D. description of any internal and external pumps; and <br /> E. sketch or drawing of tank including dimensions. <br /> 3. documented age of the tank system (if tank was previously used), if available, (otherwise, an estimate of the <br /> age); <br /> 4. description and evaluation of any leak detection equipment; <br /> 5. description and evaluation of any corrosion protection equipment, devices, or material; <br /> 6. description and evaluation of any spill prevention or overfill equipment; <br /> 7. description and evaluation of secondary containment for the tank system including applicable secondary <br /> containment for ancillary equipment as required in subsection 66265.193(f); <br /> 8. hazardous characteristics of the wastes that have been or will be handled. <br /> Immediately amend the used antifreeze tank system assessment to include all required information and submit a <br /> copy of the amendments to the EHD. <br /> This is a Class II violation. <br /> 605 CCR 66262.34(f) Failed to completely label containers or tanks of hazardous waste. <br /> A 55 gallon blue steel drum of used absorbent was observed with only the contents labeled. A 55 gallon blue steel <br /> drum of waste absorbent was observed with no hazardous property or accumulation start date. All hazardous waste <br /> containers shall be marked with the following information: <br /> -the words "Hazardous Waste" <br /> - name and address of generator <br /> -hazardous properties (flammable, corrosive, reactive, toxic) <br /> -physical state (liquid, solid) <br /> -composition (contents) <br /> -accumulation start date <br /> Immediately label these containers and ensure that all hazardous waste containers are marked with all the required <br /> information. Since it cannot be determined how long these wastes been on site, immediately contact a licensed <br /> hazardous waste hauler to dispose of this waste under manifest and submit a copy of the manifest to the EHD. <br /> This is a repeat violation, Class II. <br /> Received by Inspector: Phone: Date: <br /> (initial): STACY RIVERA, Senior REHS (209)468-3440 06/26/2015 <br /> Page 5 of 6 <br />