My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3515
>
2200 - Hazardous Waste Program
>
PR0514502
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2019 11:43:56 AM
Creation date
11/1/2018 1:07:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0514502
PE
2228
FACILITY_ID
FA0003747
STREET_NUMBER
3515
STREET_NAME
NAVY
STREET_TYPE
Dr
City
Stockton
Zip
95203
APN
161-030-02
CURRENT_STATUS
01
SITE_LOCATION
3515 Navy Dr
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\NAVY\3515\PR0514502\COMPLIANCE INFO 1985 - 2016 .PDF
QuestysFileName
COMPLIANCE INFO 1985 - 2016
QuestysRecordDate
8/31/2017 7:31:33 PM
QuestysRecordID
3617636
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
288
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING AND REPORTING PROGRAM <br />SHELL OIL COMPANY <br />STOCKTON BULK FUEL DISTRIBUTION FACILITY <br />WASTEWATER TREATMENT SYSTEM DISCHARGE <br />SAN JOAQUIN COUNTY <br />RECEIVING WATER MONITORING <br />-3- <br />Receiving water samples shall be collected from two locations as identified below. Samples should be <br />representative of the volume and nature of the receiving water. Time of collection of a grab sample shall <br />be recorded. The following shall constitute the receiving water monitoring program: <br />P.-1 The San Joaquin River near the point of discharge <br />R-2 Approximately 500 feet downstream of the discharge point (Flow direction reverses due <br />to tidal action and releases to the water projects. The Discharger shall note which direction <br />is downstream at the time of sample collection) <br />To be collected between 8-12 hours after the onset of the discharge, and <br />prior to terminating the discharge <br />REPORTING <br />Monitoring results shall be submitted by the 20th day of the month. following the end of the calendar <br />quarter. <br />In reporting the monitoring data. the Discharger shall arrange the data in tabular form so that the date, <br />the constituents. and the concentrations are readily discernible. The data shall be summarized in such <br />a manner to illustrate clearly whether the discharge complies with waste discharge requirements. <br />If the Discharger monitors any pollutant at the locations designated herein more frequently than is <br />required by this Order, the results of such monitoring shall be included in the calculation and reporting <br />of the values required in the discharge monitoring report form. <br />Type of <br />Sampling <br />Constituents <br />Units <br />Sample <br />Frequency <br />Dissolved Oxygen <br />mg/l <br />Grab <br />Monthly' <br />pH <br />pH Units <br />Grab <br />Monthly' <br />Temperature <br />°C <br />Grab <br />Monthly' <br />.-Ammonia <br />mg/1 <br />Grab <br />Monthly' <br />To be collected between 8-12 hours after the onset of the discharge, and <br />prior to terminating the discharge <br />REPORTING <br />Monitoring results shall be submitted by the 20th day of the month. following the end of the calendar <br />quarter. <br />In reporting the monitoring data. the Discharger shall arrange the data in tabular form so that the date, <br />the constituents. and the concentrations are readily discernible. The data shall be summarized in such <br />a manner to illustrate clearly whether the discharge complies with waste discharge requirements. <br />If the Discharger monitors any pollutant at the locations designated herein more frequently than is <br />required by this Order, the results of such monitoring shall be included in the calculation and reporting <br />of the values required in the discharge monitoring report form. <br />
The URL can be used to link to this page
Your browser does not support the video tag.