Laserfiche WebLink
1 Site Safety Plan • • <br /> Job No. 4780201 Page 12 <br /> VIII. CONTAMINANT ACTION LIMITS <br /> ' This Section discusses the levels at which additional actions to insure worker <br /> safety are implemented. All individuals working within the Exclusion Zone, or in <br /> tareas where concentrations of airborne contaminants exceed the Action Limits <br /> presented in Table 4 below, must wear approved air purifying respirators <br /> equipped with organic vapor cartridges. Should contaminant levels exceed <br /> respirator cartridge capacities, an upgrade to Level B PPE respiratory protection <br /> (Self-Contained Breathing Apparatus (SCBA]) will be required. Saranex suits <br /> ' must be worn at all times by individuals working within the Exclusion Zone. <br /> ' TABLE 4 - HAZARD EVALUATION GUIDELINES <br /> ' CONTAMINANT ROE PEL IDLH ACTION <br /> LIMIT <br /> ' Diesel C,IG,IH NE NE NE <br /> Gasoline C,IG,IH 300 ppm 3,000 ppm 150 ppm <br /> ' Benzene C,IG,IH 1 ppm 3,000 ppm gppm <br /> Toluene C,IG,IH 100 ppm 3,000 ppm <br /> Ethylbenzene C,IG,IH 100 ppm 2,000 ppm Xylenes C,IG,IH 100 ppm 1,000 ppm <br /> tROE = Route of Entry IG = Ingestion <br /> ' PEL CAL/OSHA Permissible Exposure Limit IH Inhalation <br /> IDLH Immed. Dangerous to Life & Health PPM Parts per million <br /> C = Dermal Contact NE = None Established <br /> t <br /> 1 <br /> 1 <br /> t <br />' EZC, Inc. <br /> Apri/4, 1997 <br />