NOV-16-2001 1215 P.03i20 <br /> 10 September 2001 <br /> AGB-NC Project No. 01-0861 <br /> Page 2 of 4 <br /> According to the CV-RWQCB IS January. 2001 letter, the maximum and average Ili-leachable <br /> Chromium VI repotted.in samples collected-by MonierL.ifetile was 20 micrograms per liter.(pg(L), <br /> which may he partially erroneous. <br /> AGE was retained to collect sample#from the waste the stockpile located at the subject site it 925 <br /> West Anderson Street, Stocktor9.Caisfornia.)&.Ross Atkinson was contacted by AGE to determine <br /> the'mamber of samples and obtsW approval of the sampling method prior to collection of samples. <br /> Pursuant to#telephone conference with Mr:Atkinson,the scope of work included-the collecdari and <br /> analysis of twenty concrete waste file samples. Sample locations were determined using a 20-foot <br /> grid pattern over the orginally 200-foot by 280-foot stockplle which was divided into 132 equal grid <br /> squares(Fds). Pursuant to the suggestion of W.Atkinson, Et.random number generator was then <br /> used to determine the twenty grids to be sampled. <br /> Grids sampled are illustrated on Figure 2, After construction of the stockpile map,'but prior to <br /> sainpling an 23 August 2001,the stockpile had been consolidaWd and the aerial dimensions reduced; <br /> therdbre, some of the randomly selected Vids could not be sampled.Where the randomly-selected <br /> Sad could not be sampled,the closest Ascent,unsampled grid was chosen. yi <br /> r <br /> a .. <br /> 2A. WASTI TILE SAMPI.Z COLLECTION PROCMURES <br /> Samples were collected on 23 August 2001 utilizing an excavator to pothole in each desired <br /> sampling location. samples were oblleeted from the excavator bucket using a metric soil sampler <br /> and 2-inch by 6-inch brass sleeves. The sleeves were packed fill of soil to minimize head apace, the <br /> ends were covered with TeSbn sheets and were then sealed with a plastic end cap and duct tape. <br /> Each sleeve was labeled with the sample identification, collection date and time.and with the sample <br /> collectors initials. <br /> The preserved sample was thenstaredin a chilled container pending shipment to a OM-certified <br /> analytical laboratory under chain of custody for analysis- -Each sample was analyzed for the <br /> following; <br /> • Total petroleum hydrocarbon`s quay fieri as diesel(TPH-d) by EPA Method 80ISM; <br /> +. TPH-d(EPA'80I S"using a WET Method with DI water; and, <br /> • IlexavalerA chromium (Chromium VI) by EPA Method. 7196A (Waste Bxtraction Test; - <br /> WET)using dc-ionized(AI)water. <br />