My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PICCOLI
>
1990
>
2200 - Hazardous Waste Program
>
PR0514089
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/5/2022 2:43:26 PM
Creation date
11/1/2018 4:24:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0514089
PE
2247
FACILITY_ID
FA0003826
FACILITY_NAME
Supervalu
STREET_NUMBER
1990
Direction
N
STREET_NAME
PICCOLI
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
10121001
CURRENT_STATUS
01
SITE_LOCATION
1990 N PICCOLI RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\P\PICCOLI\1990\PR0514089\RTC 4_18_08 INSPECTION\RTC 4_18_08 INSPECTION.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1282
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4.2 ARM (Association of Rotational Molders) Standards: Low Temperature Impact Resistance <br />(Falling Dart Test Procedure) <br />4.3 ANSI Standards: B-16.5 Pipe Flanges and Flanged Fittings <br />4.4 OSHA Standards: 29 CFR 1910.106 Occupational Safety and Health Administration, <br />Flammable and Combustible Liquids <br />4.5 UBC CODE: Uniform Building Code 2006 Edition <br />4.6 IBC CODE: International Building Code 2009 Edition <br />4.7 CBC Code: California Building Code 2010 Edition <br />RECEIVED <br />4.8 NSF/ANSI Standard 61 — Drinking Water System Components (Type II resin) JUL 2 8 2014 <br />4.9 40 CFR -264.193 <br />ENVIRONMENTAL HEALTH <br />5. Submittals DEPARTMENT <br />5.1 Drawings and Data: The manufacturer's shop drawings shall be approved by the engineer or <br />contractor prior to the manufacturing of the tank(s). Data and specifications for the equipment <br />shall include, but shall not be limited to the following. <br />5.2 Contractor shall submit for review sufficient literature, detailed specifications, and drawings to <br />show dimensions, materials used, design features, internal construction, weights and any <br />other information required by the ENGINEER for review of storage tanks and accessories. <br />5.3 Information to be included with submittals are specified below: <br />5.3.1 Shop drawings for the tanks shall include as a minimum the following: <br />a) Service Conditions: Chemical environment and temperature. <br />b) Statement that fabrication shall be in accordance with ASTM D 1998, where <br />applicable. <br />c) Sizing and description of the fittings and accessories for each tank that are to be <br />supplied by the tank manufacturer. <br />d) Layouts and assembly schedules for each tank identifying the location and elevation <br />from the bottom of the tank for all connections and appurtenances supplied by the <br />tank manufacturer. <br />5.3.2 Resin - A copy of the resin data sheet from the resin manufacturer for the tank is to be <br />supplied and the tank manufacturer is to certify that it will be the resin used in the <br />manufacture of the tank. Verification may be required if the resin is to be FDA or NSF 61 <br />listed. <br />5.3.3 Wall thickness - Prior to the manufacture of the tank the designed wall thickness audit <br />is to be supplied based upon 600 psi hoop stress (ASTM D 1998) @ 100 degrees F. (Note: <br />See 9.1.2 for chemicals being stored above 100 degrees F) <br />5.3.4 Tank restraint — If supplied, the drawings and calculations for the system are to be <br />provided. Note: Wet stamped or site specific drawings and calculations may be required. <br />
The URL can be used to link to this page
Your browser does not support the video tag.