My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1994 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SWIFT
>
781
>
2200 - Hazardous Waste Program
>
PR0516666
>
COMPLIANCE INFO 1994 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 9:07:23 AM
Creation date
11/1/2018 5:33:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
1994 - 2015
RECORD_ID
PR0516666
PE
2220
FACILITY_ID
FA0012730
FACILITY_NAME
FLAME TRANS INC
STREET_NUMBER
781
STREET_NAME
SWIFT
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
CURRENT_STATUS
02
SITE_LOCATION
781 SWIFT WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\SWIFT\781\PR0516666\COMPLIANCE INFO 1994 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 1994 - 2015
QuestysRecordDate
8/31/2017 11:35:07 PM
QuestysRecordID
3619246
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
186
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a I <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.s'gov.or leehd <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Data: <br /> CENTRAL VALLEY TRAILER REPAIR INC 781 SWIFT WAY STOCKTON September 17 2015 <br /> Universal Waste <br /> 705 CCR 66273.33(c) Failed to properly manage mercury containing universal waste ❑V a R ❑COS <br /> 706 CCR 88273.33.5 Failed to properly manage universal waste electronic devices,CRTs or CRT glass ❑V ❑R ❑COS <br /> 707 HSC 25201.16(e) Failed to manage aerosol cans In a manner that prevents the unauthorized release of waste o V o R ❑COS <br /> 708 HSC 25201.16(0 Failed to properly manage containers of waste aerosol cans ❑V ❑R ❑COS <br /> 709 HSC 25201.16(g) Failed to store used aerosol cans In an accumulation container ❑V ❑R ❑COS <br /> 710 HSC 25201A6(h)(4) No written operating procedure for aerosol can processing o V ❑R ❑COS <br /> 711 HSC 25201.160 Failed to submit or amend notification for aerosol can processing ❑V ❑R ❑COS <br /> 712 CCR 66273.34 Failed to label universal waste to identify type of universal waste ❑V u R ❑COS <br /> 713 CCR 66273.35 Stored UW onsite greater than one year or was unable to demonstrate the time UW has been stored o V a R n COS <br /> 714 CCR 66273.36 Failed to train employees and maintain records on UW handling and emergency procedures n V ❑R a COS <br /> 715 CCR 66273.39 Failed to keep complete records of each shipment of universal waste for three years ❑V u R ❑COS <br /> Other Violations <br /> 3010 See below Unlisted Administration/Documentation violation ❑V a R a COS <br /> 3020 See below Unlisted Training violation ❑V o R ❑COS <br /> 3030 See below Unlisted Operations/Maintenance violation o V ❑R o COS <br /> 3040 See below Unlisted Release/Leaks/Spills violation ❑V o R ❑COS <br /> 3050 See below Unlisted AbandonmenYlllegal DlsposaVUnauthorized Treatment violation a V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 CCR 66262.34(d)(2)No modified contingency plan. <br /> An emergency coordinator and modified contingency plan information is outdated. There must be at least one <br /> emergency coordinator on site or on call to coordinate emergency response measures,and the following information <br /> must be posted by a phone: the name and phone number of the emergency coordinator, location of fire extinguishers, <br /> spill control equipment, and if present, fire alarm; and the phone number of the fire department, unless the facility has <br /> a direct alarm. Immediately appoint an emergency coordinator and post the required information by a phone. A form <br /> is provided that can be used for this purpose. torrAed /S fi%&d Ovf bfcf, <br /> This is a repeat violation, Class 11. V fj'l hl d A/ �o�Cq[j L sow/io/n . <br /> 109 CCR 66262.40(a)Failed to keep signed copy of manifests from the designated facility for three years. <br /> Copies of uniform manifests for the disposal of hazardous waste for the last three years were not found on site. <br /> Hazardous waste generators shall retain copies of all manifests signed off by the disposal facility and all receipts used <br /> in a consolidated manifesting procedure on site for three years and have them readily available for review. Immediately <br /> locate a copy of all manifests and receipts for the last three year//s, m� aintain them on site, and submit copies to the <br /> EHD. 1'''ve Gn4f4okd /�r4 s D/% /�c�e%its / /�'terhonkl <br /> This is a repeat violation, Class ll. CA16 JrAd 1n4r17FCJ75r- 7 Q L'Iked r 'J rfd/ h"wtrJ <br /> Will /mallei/ 76 /rte b - 3,orn <br /> Received by Inspector: Phone: Date: <br /> (Initial): STACY RIVERA, Senior REHS (209)468-3440 09/17/2015 <br /> Pago 3 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.