San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California95205-6232 <br /> Telephone:(209) 468-3420 Fax: (209) 468-3433 Web:www.sigov.orulehd <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ARYSLER JEEP DODGE 1145 W YC "ITE AVE. MAN' (larch 31 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS 11,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> HSC 25185(c)(3) Failed to submit a written response within 30 days of receiving an inspection report. <br /> inspection was last done on 4-27-15 and an inspection report was issued identifying information to be submitted to <br /> this site into compliance. This information was required to be submitted 30-days from receipt of the complet, <br /> elation report. This information was received on 2-26-16 resulting in a non-compliant status for this facility. All <br /> ator that receives an inspection report shall have 30 days to submit a written response that includes a statement <br /> i;umenting corrective actions taken or proposing corrective actions which will be taken. Ensure that a written <br /> response documenting corrective actions taken or proposed is submitted within 30 days of receiving an inspection <br /> nort. <br /> ,is is a Class II violation. <br /> 202 HSC 25189.5(a) Disposed or caused disposal of HW at an unauthorized point. <br /> A large accumulation of florescent lamps(4 to 6 feet in length) and large (4-6 inches in diameter) industrial size bulbs <br /> was observed on the ground inside the fenced enclosure located beneath electrical power lines. Some of the <br /> florescent tubes were broken. Hazardous wastes shall be disposed of only by transportation to a permitted hazardous <br /> ;ste treatment, storage, and disposal facility (TSDF). Immediately cease disposal of hazardous waste onsite and <br /> ire that all future waste is hauled by a licensed hazardous waste transporter to a permitted TSDF. Submit proof of <br /> ..oi rection to the EHD. <br /> This is a Class I violation. <br /> 301 CCR 66265.31 Facility not maintained to minimize the release of a hazardous waste. <br /> A large accumulation of florescent lamps(4 to 6 feet) in length and large industrial size bulbs was observed on the <br /> ground inside the fenced enclosure located below beneath electrical power lines. Also, metal fines were noted on the <br /> shop floor next to the metal grinding equipment. Facilities shall be maintained and operated to minimize the possibility <br /> of a fire, explosion, or release of hazardous waste to air, soil, or surface water which could threaten human health or <br /> the environment. Immediately clean all spills and leaks, and manage them according to Title 22 hazardous waste <br /> regulations. Submit a statement and supporting documentation explaining how this waste was managed. <br /> This is a repeat violation, Class It. <br /> 304 CCR 66265.35 Failed to maintain adequate aisle space for unobstructed response to emergencies. <br /> Several 55-gallon containers, located inside the hazardous waste accumulation area, were stored in a manner which <br /> prevented the unobstructed movement around the containers and impeded the view of the hazardous waste containe <br /> labels. Adequate aisle space shall be maintained to allow the unobstructed movement of personnel, fire protection, <br /> spill control equipment, and decontamination equipment to all areas of facility operation in an emergency. <br /> Immediately maintain aisle space to allow the unobstructed movement of personnel, fire protection, spill control <br /> equipment, and decontamination equipment to any area of facility operation in an emergency. <br /> s is a repeat violation, Class It. <br /> Page 6 of 8 <br />