My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAMBRIDGE
>
16470
>
2300 - Underground Storage Tank Program
>
PR0231532
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/4/2022 2:28:59 PM
Creation date
11/2/2018 3:58:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231532
PE
2351
FACILITY_ID
FA0000185
FACILITY_NAME
CITY FOOD & LIQUOR
STREET_NUMBER
16470
STREET_NAME
CAMBRIDGE
STREET_TYPE
ST
City
LATHROP
Zip
95330
APN
19643032
CURRENT_STATUS
03
SITE_LOCATION
16470 CAMBRIDGE ST
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CAMBRIDGE\16470\PR0231532\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
10/23/2012 8:00:00 AM
QuestysRecordID
132740
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
115
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUNDSTORAGETANK <br /> MONITORING PLAN-(Pae I of 2) <br /> TYPE OF ACTION ❑ 1.NEW PLAN ® 2.CHANGE OF INFORMATION 490'1 <br /> PLAN TYPE N 1.MONITORING IS IDENTICAL FOR ALL UST's AT THIS FACILITY. '190.3 <br /> (Check one itmn only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(l) <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Um Only) <br /> BUSINESS NAME(Same as FACILITY NAME) Circle KStore #2701205 ' <br /> BUSINESS SITE ADDRESS 16470 Cambridge Street 1°3. CITY Lathrop IM. <br /> IL EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,amt calibration of monitoringequipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed of the frequency <br /> specified by the equipment manufacturers'instructions,or annually,whichever is more frequent,and dlnt such work must be performed by qualified personnel, <br /> 23 CCR 263212634,2638,2641 <br /> MONIT'011ING EQUIPMENT IS SERVICED N L ANNUALLY ❑ 99.OTHER(Specify): a90a4 <br /> III.MONITORING LOCATIONS <br /> ®L NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN. ❑2.SITE PLOTPLAN/MAP PREVIOUSLY SUBMITTED. (23 CCR§2632, <br /> 2634)4964 _ <br /> IV.TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S): <br /> 1.CONTINUOUS ELECTRONICTANKMONITORING OF ANNULAR(WrEERSTITIAL)SPACES)ORSEC,ONDARY CONTAINMENT a9a-s <br /> VAULT(S)WITH AUDIBLE AND VISUAL ALARMS. (23 CCR§2632,2634) <br /> SECONDARY CON'fAINMF:Nf IS: ❑ &DRY N b.LIQUID FILLED ❑ c.PRESSURIZED ❑d.UNDER VACUUM 4146 <br /> PANEL MANUFACTURER: Veeder Root 4904. MODEL#: TLS-350 4908 <br /> LEAK Sr:NSOR MANUFACTURER- Veeder Root 4909 MODEL HIS): 794380-303 49u-ic <br /> ❑ 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED T'O MONITOR SINGLE WALL TANK(S).(23 CCR§2643) <br /> PANELMANUFACTURER: 494"12' MODEL.#: <br /> IN-TANK PROBF.MANUFAC .IRER: <br /> LEAK TEST FREQUENCY: ❑ n.CONTINUOUS ❑ b.DAILYMIGH'!LY ❑ c WEEKLY 49o-m <br /> ❑ d.MONTHLY 0 e.OTHER(Specify): M-11 <br /> PROGRAMMED'ITSTb: ❑ a-0.1g h. ❑ h.0.2 .h. ❑ c.OTHER(Specify): 49o.Iz <br /> P� g�P 49o.ro <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION(23 CCR 62646.1): 990'30 <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)(23 CCR§2645). TESTING PERIOD: ❑ n.36 HOURS ❑ b.60 HOURS 449oei <br /> S.TANK INTEGRITY TESTING(23 CCR§2643.1): M603 <br /> TEST FREQUENCY: 0 a.ANNUALLY El b.BIENNIALLY E] c.OTHER(Specify): :0.i <br /> ❑99.OTHER (Specify): _ 49an <br /> V.PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S)(Check all that apply) <br /> I.CONTINUOUS MONITORING OF PIPE/PIPING SUMPS)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE AND .99 <br /> VISUAL ALARMS. (23 CCR§2636) <br /> SECONDARY CONTAINMENT IS:Na.DRY ❑b.LIQUID FILLED ❑c.PRESSURIZED ❑d.UNDER VACUUM 49o-39 <br /> PANEL MANUFACTURER__ Veeder Root _99040 I MODEL#: TLS-350 49013 <br /> 490-t1) _ _ <br /> LEAK SENSOR MANUFACTURER: Veeder Root MODEL#(5)_ 794380-2084W13_- <br /> PIPING LEAK ALARM'1'RIGGERS AUTOMATIC PUMP i.e.,TURBINE)SHUTDOWN. N e.YES ❑b.NO 190'14 <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. N a.YES ❑b.NO 490.35 <br /> 2.MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF <br /> _PRODUCT_FL_OW_WHEN_A LEAK IS DETECTED2. CCR§2636L _. ___..____.__....__.._..._.__ 490-36 <br /> MLLD MANUFACTURER(S):Regular-FE Petro/Premium-Red Jacket j90' MODEL#(S):Reg.#MLD/Prem.#FXI V 490-38 <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS3.0 g.p.h.LEAK TESTS (23 CCR§2636) 49039 <br /> ELLD MANUFACfURERMANUFACTURERS) 090'<° MODEL#(S). "T9o-4i <br /> .__._..__ ..__...___T- _-.-2--'MINIMUM <br /> -.. UM AN---____._.____...__._. <br /> PROGRAMMED M LINE LEAK TEST: ❑ I.MINIMUM MONTHLY 0.2 g.p.h. ❑ 2MINIMUM ANNUALOA g.p.h. ^9°43 <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑e.YES 0 b.NO "9V-01 <br /> ELLD FAILURE/DISCONNECTiON TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑n.YES ❑b.NO a9049 <br /> 4.PIPE INTEGRITY TESTING 49045 <br /> TESTFRE UENCY a.ANINUALLY b.EVERY3YEARS El c.OTHER(Specify) 490.4649047 <br /> 5,VISUAL PIPE MONITORING. 49048 <br /> FREQUENCY ❑ a.DAILY ❑ b.WEEKLY ❑c.MIN.MONTHLY&EACH TIME SYSTEM OPERATED- 49049 <br /> •Albw9d 2,m90ami N,mtu4M m1 tm ILcI ' 9al HSC 353815 <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA 123 CCR§2636(x)(3)1. 490.50 <br /> Cj 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6,7 IS CONNECTED TO THE TANX SYSTEM <br /> 490.51 <br /> -" 49?51 <br /> ❑ 99.OTHER(Specify) 490-51 <br />