My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1997
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAMBRIDGE
>
16470
>
2300 - Underground Storage Tank Program
>
PR0231532
>
INSTALL_1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:36 AM
Creation date
11/2/2018 3:58:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1997
RECORD_ID
PR0231532
PE
2351
FACILITY_ID
FA0000185
FACILITY_NAME
CITY FOOD & LIQUOR
STREET_NUMBER
16470
STREET_NAME
CAMBRIDGE
STREET_TYPE
ST
City
LATHROP
Zip
95330
APN
19643032
CURRENT_STATUS
03
SITE_LOCATION
16470 CAMBRIDGE ST
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CAMBRIDGE\16470\PR0231532\INSTALL 1997.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NEW UST INSTALLATION INSPECTION RECORD <br /> FACILITY NAME: - <br /> FACILITY ID# ADDRESS• <br /> CAPACITY: UL# <br /> 1'���g TANK MODEL/MATERIAL: {�_, ,1_ , <br /> /Je:�ypYl <br /> PRODUCT: <br /> A I <br /> P N <br /> P ) ALL TANKS TO BE INSTALLED AND TESTED IN ACCORDANCE R T WITH MANUFACTURER WRITTEN SPECIFICATIONS <br /> 0 1 <br /> V A <br /> E L <br /> D S <br /> DATE ITEM OR EQUIPMENT INSPECTED <br /> 1. UST PLANS SUBMITTED/ FEES PAID <br /> (H+S CODE 25287) <br /> 7 2. UST iNSTAILATfON PLANS APPROVED <br /> INITIAL INSPECTIONS <br /> I= ' 3. INSPECTION AND TEST OF SECONDARY CONTAINMENT: HOLIDAY: <br /> VACUUM: SOAP: PSI: G NRS/ IN: [. O BRINE(LIQUID ANNULAR): OTHER: <br /> 4. PRIMARY TANK TEST: PSI: NRS/MIN: <br /> 5. TANK APPROPRIATELY PLACED WITH APPROVED BACKFILL (API/PEI) <br /> PIPING INSPECTIONS <br /> 6. PRIMARY PIPING TEST (MINIMUM 40 PSI/30 MIN) .S PJJ —40 NM (CCR 2636 (U) <br /> L_1I 7. SECONDARY PIPING CONTAINMENT TEST PSI./0.S`HRS/MIN:Jt U OTHER: (CCR 2636 (e)) <br /> _4 ✓ 4 8. LAKE TEST ON ALL SUMPS (24 HR. MINIMUM) NRS: (CCR 2635 (a) (4)) <br /> ✓ 23. 9. UNUSED TANK OPENINGS SEALED AND CORROSION PROTECTED PEI <br /> D 10. OVERSPILL PERFORMANCE TEST (CCR 2635 (b) (1) (C)) <br /> a' a'111 1. ALL PIPING AND FITTINGS CORROSION PROTECTED (CCR 2636 (b)) <br /> a_ �_ ✓ 12. PIPING SLOPES TO COLLECTION SUMP (CCR 2636 (c)(1)) <br /> FINAL INSPECTION <br /> 13. PERFORMANCE TEST FOR "ALL" MONITORING PROBES (CCR 2632 (c) (2)) <br /> IM 14. PERFORMANCE TEST OF CONTINUOUS MONITORING SYSTEM (PANEL) (CCR 2632 (c) (2)) <br /> 15. PERFORMANCE TEST OF LINE LEAK DETECTION (CCR 2643 (c) (1)) <br /> 16. PERFORMANCE TEST OF AUTOMATIC PUMP SYSTEM SHUT-OFF (CCR 2636 (B)) <br /> 1 445 17. BALL FLOAT VALVES INSTALLED <br /> q lop, 18. OVERFILL PROTECTION INSTALLED/APPROVED (CCR 2635 (b) (2)) <br /> 19. TANK ACCESS PORTS BROUGHT TO GRADE (LOCKED AND WATERTIGHT) API <br /> 20. TANK INTEGRITY TEST (PASSING HARD COPY) (LCR 2635 (a) (5)) <br /> 21. MONITORING PLAN, RESPONSE PLAN AND LOG BOOK ON SITE (CCR 2632 (d)) <br /> 22. "C" FORM COMPLETED AND SUBMITTED (CCR 2635 (d)) <br /> 23. MONITORING METHOD FOR ALL TANKS AND PIPING APPROVED (CCR 2630-2636) <br /> 24. ALL CONDITIONS MET; FACILITY PERMIT ISSUED (H+S CODE 25284) <br /> COMMENTS: <br /> EH23-006 7/97 <br /> 10 <br />