Laserfiche WebLink
DAY OWNIGHT E R T I F I C A T E. NO. 32380 <br /> TELEPHONE I <br /> (510) 235-1393 CERTIFIED SERVICES COMPANY CUSTOMER <br /> 255 Parr Boulevard • Richmond, California 94801p5yryc� <br /> JOB NO. <br /> HENDERSON CONST. <br /> FOR: ERICKSON, INC. TANK NO. 25952 <br /> LOCATION: <br /> RICHMOND. CA DATE: 22TIME: <br /> 5/99 2:13:00 PM <br /> VISUAL GASTECH/1314 SMPN UG <br /> =ST METHOD LAST PRODUCT <br /> This is, to certify that I have personally determined that this tank is in accordance with the American <br /> Petroleum Institute and have found the condition to be in accordance with its assigned designation. <br /> This certificate is based on conditions existing at the time the inspection herein set forth was <br /> completed and is issued subject to compliance with all qualifications and instructions. <br /> 12,000 GALLON TANK SAFE FOR FIRE <br /> TANK SIZE CONDITION <br /> OXYGEN 20 9%LOWER EXPLOSIVE LIMIT LESS THAN 0.1%ERICKSON, INC. HERBY CERTIFIES THAT THE <br /> REMARKS: <br /> ABOVE NUMBERED TANK HAS BEEN CUT OPEN, PROCESSED,AND I HLKI=�-VRI=Ul=�51 HUYLU A I UUR­ <br /> PERMITTED <br /> ERICKSON IAIL HAS THE APPORRIATE PFRMITC FQVe AND HA.- ArOFPTpn THF TANK.RHIPPPD TO US <br /> FOR PROCESSING. <br /> In the event of any physical or atmospheric changes affecting the gas-free conditions of the above tanks, or if in any doubt, <br /> immediately stop all hot work and contact the undersigned. This permit is valid for 24 hours if no physical or atmospheric <br /> changes occur. _ <br /> STANDARD SAFETY DESIGNATION <br /> SAFE FOR MEN: Means that in the compartment or space so designated (a) The oxygen content of the atmosphere is at least <br /> 19.5 percent by volume; and that (b) Toxic materials in the atmosphere are within permissable concentrations; and (c) In the <br /> judgment of the Inspector, the residues are not capable of producing toxic materials under existing atmospheric conditions <br /> while maintained as directed on the Inspector's certificate. <br /> SAFE FOR FIRE: Means that in the compartment so designated (a) The concentration of flammable materials in the <br /> atmosphere is below 10 percent of the lower explosive limit; and that (b) In the judgment of the Inspector, the residues are <br /> not capable of producing a higher concentration that permitted under existing atmospheric conditions in the presence of fire <br /> and while maintained as directed on the Inspector's certificate, and further, (c) All adjacent spaces have either been cleaned <br /> sufficiently to prevent the spread of fire, are satisfactorily inerted, or in the case of fuel tanks, have been treated as deemed <br /> necessary by the Inspector. <br /> The undersi ned represe ta 'v cknowledges receipt of this certificate and understands the o itions and limit ions under <br /> which ' iss ed. .. <br /> G <br /> EPR E TATIVE TITLE INSPECTOR <br /> roco< <br />