Laserfiche WebLink
GAY OR' NIGHT - ERTIFICATE NO. 32377 <br /> TEL(510)235-01393 CERTIFIED SERVICES COMPANY CUSTOMER <br /> 255 Parr Boulevard • Richmond, California 94801 JOB NO. <br /> HENDERSON CONST. <br /> FOR: <br /> ERICKSON, INC. TANK NO. 25460 <br /> RICHMOND.CA 3/1/99 2:11:29 PM <br /> LOCATION: DATE: TIME: <br /> -EST METHOD <br /> VISUAL GASTECH/1314 SMPN LAST PRODUCT UG <br /> This is to certify that I have personally determined that this tank is in accordance with the American <br /> Petroleum Institute and have found the condition to be in accordance with its assigned designation. <br /> This certificate is based on conditions existing at the time the inspection herein set forth was <br /> completed and is issued subject to compliance with all qualifications and instructions. <br /> TANK SIZE <br /> 969 LF GALLON TANK CONDITION SAFE FOR FIRE <br /> REMARKS: OXYGEN 20.9%LOWER EXPLOSIVE LIMIT LESS THAN 0.10%ERICKSON, INC. HERBY CERTIFIES THAT THE <br /> ABOVE NUMBERED TANK HAS BEEN CUT OPEN,PROCESSED,AND THEREFORE DESTROYED AT OUR <br /> PERMITTED HAZARDOUS WASTE FACILITY. <br /> ERICKSON, INC. HAS THE APROPRIATE PERMITS FOR,AND HAS ACCEPTED THE TANK SHIPPED TO US <br /> In the event of any physical or atmospheric changes affecting the gas-free conditions of the above tanks, or if in any doubt, <br /> immediately stop all hot work and contact the undersigned. This permit is valid for 24 hours if no physical or atmospheric <br /> changes occur. <br /> STANDARD SAFETY DESIGNATION <br /> SAFE FOR MEN: Means that in the compartment or space so designated (a) The oxygen content of the atmosphere is at least <br /> 19.5 percent by volume; and that (b) Toxic materials in the atmosphere are within permissable concentrations; and (c) In the <br /> judgment of the Inspector, the residues are not capable of producing toxic materials under existing atmospheric conditions <br /> while maintained as directed on the Inspector's certificate. <br /> SAFE FOR FIRE: Means that in the compartment so designated (a) The concentration of flammable materials in the <br /> atmosphere is below 10 percent of the lower explosive limit; and that (b) In the judgment of the Inspector, the residues are <br /> not capable of producing a higher concentration that permitted under existing atmospheric conditions in the presence of fire <br /> and while maintained as directed on the Inspector's certificate, and further, (c) All adjacent spaces have either been cleaned <br /> sufficiently to prevent the spread of fire, are satisfactorily inerted, or in the case of fuel tanks, have been treated as deemed <br /> necessary by the Inspector. <br /> The undersigned representative dges receipt of this certificate and understands t co ditions and I i ations under <br /> which it wa issued. <br /> REP ESENT TIV TITLE INSPECTOR <br />