Laserfiche WebLink
' D PROGRAM CONSOLIDATED F YAQ PW qA-V <br /> TANKS <br /> UNDERGROUND STORAGE TANKS - TANK RAGE 1 <br /> s 1,9- (two Pages Per tank) <br /> Page�Zc JI <br /> .TWE OF ACTION ❑1 NEW SITE PERMIT ® 4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Cl,cols one km only) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Specify reason-for kcal we only) (Specify rowers,-for local we only) ❑ 8 TANK REMOVED 430 <br /> --L BUSINESS NAME(Smew PACIIJTY NAMam DBA-Doing aware.As) 3 FACILITY ID: <br /> Van De Pol Ent rises <br /> LOCATION WITHIN SITE(OPtioneo 47l <br /> Northwest side of site <br /> 1.TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID#3 432 TANK MANUFACTURER 433COMPARTMENTALIZED TANK Yes No 434 <br /> UNKNOWN TAO 3�l`oZO UNKNOWN H•Yes,agleernePaBeaaan<oWanma <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 1988 12,0Co 1 <br /> ADDITIONAL DESCRIPTION(For kd we only) 438 <br /> IL TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 040 <br /> ❑,1. MOTOR VEHICLE FUEL Ela. REGULAR UNLEADED ❑2. LEADED [15. JET FUEL <br /> (Irmerk complem Pearokmm Type) ❑lb. PREMIUM UNLEADED [13. DIESEL ❑6. AVIATION FUEL <br /> ❑2. NON-FUEL PETROLEUM ❑10. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER <br /> ❑3. CHEMICAL PRODUCT COMMON NAME (6om llaardow Maaws lrrsawo y age) 441 CAS#(fora Haaardow Materials Inventory page) 442 <br /> 04. HAZARDOUS WASTE UNKNOWN <br /> (Include Used oil) <br /> [195.UNKNOWN <br /> III. TANK CONSTRUCTION <br /> TYPE OF TANK 1. SINGLE WALL 0 3. SINGLE WALL WITH 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Chckomhemonly) EXTERIOR MEMBRANE LINER 095. UNKNOWN <br /> 02. DOUBLE WALL ❑4. SIGNLE WALL IN VAULT ❑99. OTHER <br /> TANK MATERIAL-prim twk ❑I. BARE STEEL 03. FIBERGLASS/PLASTIC [13. CONCRETE 0 95. UNKNOWN 443 <br /> (Chock one am only) ❑2. STAINLESS STEEL [34. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPTIBLE W/loOY.METHANOL ❑99.OTHER <br /> REINFORCED PLASTIC <br /> TANK MATERIAL-secondary tank 1. BARE STEEL ®3. FIBERGLASS/PLASTIC 0 <br /> 5. CONCRETE ❑95. UNKNOWN 445 <br /> (Chock om dem only) [12. STAINLESS STEEL [34. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPTIBLE W/100%.METHANOL ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10.COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING 1.RUBBER LINED 0 3.EPDXY LINING ❑5.GLASS LINING 95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING 1816 UNLINED ❑99 OTHER <br /> (Check ane w,rn.Iy) (For local we only) <br /> OTHER CORROSION ❑ [MANUFACTURED CATHODIC ❑3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN us DATEINSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION [14 IMPRESSED CURRENT ❑99 OTHER <br /> (Check om hem only) ❑2 SACRIFICIAL ANODE (Fm local we only) <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE(loaf as.only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Cheek all that sqly) ®1 SPILL CONTAINMENT 2003 01 ALARM 2003 ❑3 FILL TUBE SHUT OFF VALVE <br /> ®2 DROP TUBE 2003 0 2 BALL FLOAT 2003 ❑4 EXEMPT <br /> ®3 STRIKER PLATE 1988 <br /> IV.TANK LEAK DETECTION(A description oftba rmnhoring pmgran shall be submitted m the local asswer) <br /> IF SINGLE WALL TANK(clnck 41 tho,apply) 053 IF DOUBLE WALL TANK OR TANK WITH BLADDER 03a <br /> (Clack oro kemonly) <br /> ❑1 VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MTG) ❑1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> (SIR) BIENNIAL TANK TESTING ❑99 OTHER <br /> IV.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> LED WITH INERT MATERIAL? 457 <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 655 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FIL <br /> gallons ❑Yes [I No <br /> UPCF(12/99 revised) 10 Formerly SWRCB Form B <br />