My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1033
>
2300 - Underground Storage Tank Program
>
PR0232352
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2022 2:10:29 PM
Creation date
11/2/2018 4:33:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0232352
PE
2361
FACILITY_ID
FA0003829
FACILITY_NAME
VANCO TRUCK-AUTO PLAZA
STREET_NUMBER
1033
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16323041
CURRENT_STATUS
01
SITE_LOCATION
1033 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHARTER\1033\PR0232352\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
8/8/2018 11:06:32 PM
QuestysRecordID
3201703
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Elite IV Contractors R E C RVE D <br /> 7. UNDER-DISPENSER CONTAINMENT UDC TESTING <br /> Test Method Developed By: UDC Manufacturer Industry Standard Profc4kiWl QU16 <br /> Other(Specify) <br /> Test Method Used: Pressure Vacuum ENAMN08NTAL HEALTH <br /> Other(Spec) DEPARTMENT <br /> Test Equipment Used: Caldwell Equipment Resolution: <br /> UDC#11112 UDC#8/9 SAT UDC#9110 UDC#14 SAT <br /> UDC Manufacturer:Western Western Fiberglass Western Fiberglass Western FiberglassWestern Fiberglass <br /> Fiberglass <br /> UDC Material: Fiberglass Fiberglass Fiberglass Fiberglass <br /> UDC Depth: 30" 30" 30" 30„ <br /> Height from UDC Bottom to Top 9" 9" 9" 9" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 6" 6" 6" 6., <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Ok Ok Ok Ok <br /> testing: <br /> Portion of UDC Tested <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both X Yes No NA X Yes No NA X Yes No NA X Yes No NA <br /> product and water)?* <br /> Turbine shutdown response time <br /> is system programmed for fail- X Yes No NA X Yes No NA X Yes No NA X Yes No NA <br /> safe shutdown?* _ <br /> Was fail-safe verified to be Yes No X NA Yes No X NA Yes No X NA Yes No X NA <br /> o erational?` <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> starting test <br /> Test Start Time: 9:00 9:00 9:00 9:00 <br /> Initial Reading(R,): 10" 10" 10" 10" <br /> Test End Time: 9:30 9:30 10:30 10:30 <br /> Final Reading(Rr): 10" l0" lo" 10" <br /> Test Duration: <br /> Change in Reading(RF-Rt): <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: X Pass ❑Fail X Pass C]Fail X Pass ❑Fail X Pass ❑Fail <br /> Was sensor removed for testing? Yes No NA Yes No NA Yes No NA Yes No NA <br /> Was sensor properly replaced and Yes No NA Yes No NA Yes No NA Yes No NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests} <br /> If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LGA 60) <br />