My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1033
>
2300 - Underground Storage Tank Program
>
PR0232352
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2022 2:10:29 PM
Creation date
11/2/2018 4:33:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0232352
PE
2361
FACILITY_ID
FA0003829
FACILITY_NAME
VANCO TRUCK-AUTO PLAZA
STREET_NUMBER
1033
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16323041
CURRENT_STATUS
01
SITE_LOCATION
1033 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHARTER\1033\PR0232352\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
8/8/2018 11:06:32 PM
QuestysRecordID
3201703
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Date:June 20,2018Facility Address:1033 W CHARTER WAY, STOCKTONFacility Name:VANCO TRUCK-AUTO PLAZA SUMMARY OF VIOLATIONS(CLASS I, CLASS II, or MINOR -Notice to Comply)RemarksItem #320 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements. The ATG annunciator (the sound alarm component) used as the overfill prevention system was not functional for all onsite USTs at the time of testing; the light on the overfill alarm worked at the time of testing. The annunciator wiring was repaired and retested during the inspection with passing results. This was corrected on site. <br />This is a Class II violation. <br />Overall Inspection Comments:Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement documenting the corrective actions that have been or will be taken for each violation, and any supporting paperwork, by 7-20-2018 <br />The correct positioning of the diesel T1 annular sensor couldn't be verified prior to the sensor removal. The following annular sensor (wrap around) cord lengths were measured today:91/100 octane (10,000 gallon tank)- 217"87 octane (12,000 gallon tank) - 214"diesel tanks (20,000 gallon tanks) - 252" <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner /Operator: Written Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS FACILITY BACK INTO COMPLIANCE.THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. Received by: Inspector Phone: <br />(209) 953-7699 ELENA MANZO, Lead Senior REHS <br /> Inspector:June 20, 2018 Date: <br />Printed Name and Title:Mike Boparai, Owner <br />Page 6 of 6 FA0003829 PR0232352 SC001 06/20/2018 <br />EHD 23-01 Rev. 10/31/2017 Underground Storage Tank Program OIR1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjcehd.com
The URL can be used to link to this page
Your browser does not support the video tag.