My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1033
>
2300 - Underground Storage Tank Program
>
PR0232352
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2022 2:10:29 PM
Creation date
11/2/2018 4:33:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0232352
PE
2361
FACILITY_ID
FA0003829
FACILITY_NAME
VANCO TRUCK-AUTO PLAZA
STREET_NUMBER
1033
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16323041
CURRENT_STATUS
01
SITE_LOCATION
1033 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHARTER\1033\PR0232352\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
8/8/2018 11:06:32 PM
QuestysRecordID
3201703
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN .J O A Q U I N Environmental Health Department <br /> . COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> VANCO TRUCK-AUTO PLAZA 1033 W CHARTER WAY, STOCKTON June 20, 2018 <br /> 320 1 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements ■V CR -COS <br /> 321 CCR 2635(b)(2) Overfill prevention was overridden c V o R COS <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status c V o R COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status c V o R COS <br /> 324 CCR 2717.1(g) Tampered with red tag ❑V o R COS <br /> 325 CCR 2717.1(0 Deposited petroleum into a red tagged UST c V o R c COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms o V ❑R o COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored o V o R COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements o V o R COS <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements o V c R COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system o V c R COS <br /> 331 CCR 2630(d) Secondarily contained piping not maintained to allow liquid to drain into sump o V o R COS <br /> 332 CCR 2631(b),2631(d) Primary and/or secondary containment not constructed in accordance with the established standards c V e R c COS <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not property sloped or incorrectly located check valve V e R c COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed e V o R CCS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) c V e R =COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) o V c R COS <br /> Other Violations <br /> 2010 See below Unlisted General violation c V o R c COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. Statistical inventory reconciliation was identified <br /> on Diesel TA0235201 tank form, according to Mr. Mike Boparai. statistical inventory reconciliation is not being <br /> preformed for this tank. The corrected monitoring plan was uploaded to the California Environmental Reporting <br /> System(CERS) at the time of inspection. This was corrected on site. <br /> This is a Class II violation. <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days. <br /> Annual monitoring system certification; leak detector testing, and spill container testing was performed on 6-22-2018 <br /> and a test report was submitted on 1-5-2018 , approximately 6 months late. A copy of the test report must be <br /> submitted within 30 days of the tests. Take all necessary precautions to ensure testing and submittal of test reports <br /> are performed in a timely manner. <br /> This is a Class II violation. <br /> FA0003829 PR0232352 SC001 06/20/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 3 of 6 Lnderground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton. California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.