My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1033
>
2300 - Underground Storage Tank Program
>
PR0232352
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2022 2:10:29 PM
Creation date
11/2/2018 4:33:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0232352
PE
2361
FACILITY_ID
FA0003829
FACILITY_NAME
VANCO TRUCK-AUTO PLAZA
STREET_NUMBER
1033
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16323041
CURRENT_STATUS
01
SITE_LOCATION
1033 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHARTER\1033\PR0232352\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
8/8/2018 11:06:32 PM
QuestysRecordID
3201703
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br /> SAN IOAQUIN <br /> -- - <br /> COUNTY— <br /> Underground <br /> :OUNTY---Underground Storage Tank Program inspection Report <br /> Facility Name: Facility Address: Date: <br /> VANCO TRUCK-AUTO PLAZA 10 3 W CHARTER `NAY STOCKTON June 20. 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspecticn. The existing monitoring plan was not <br /> current and/or not approved by the EHD. Statistical inventory reconciliation was identified on Diesel TA0235201 tank <br /> form, according to Mr. Mike Boparai, statistical inventory reconciliation is not being preformed for this tank. The <br /> corrected monitoring plan was uploaded to the California Environmental Reporting System (CERS) at the time of <br /> inspection. This was corrected on site. <br /> This is a Class II violation. <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> 1)The designated operator failed to check and note the correct test dates for the routine secondary containment <br /> testing on all 12 most recent designated operator inspection reports. According to EHD's records this test was <br /> conducted on 8-3-2016, however, it was listed on all above reports as 8-24-2016. During the monthly inspection, the <br /> designated operator shall check that all required testing and maintenance for the UST system have been completed <br /> and document the dates they were done. Ensure that designated operators performing monthly inspections at this <br /> facility are including all of the required information on the reports. <br /> 2)The designated operator failed to document the following alarms: <br /> -1-17 alarm (occurred 6-27-2017)was not documented on the 7-31-2017 inspection report (the prior inspection report <br /> was dated 6-22-2017) <br /> -1-24 alarm (occurred on 8-21-2017)was not documented on the 8-28-2017 inspection report (the L24 alarm was <br /> documented, however, the date it alarmed was missing) <br /> -T6 overfill(occurred on 8-31-2017)was not documented on the 9-23-2017 inspection report. <br /> -L11 alarm (occurred on 10-19-2017)was not documented on the 10-27-2017 inspection report. <br /> -L1 alarm (occurred on 10-25-2017) and 1-11 alarm (occurred on 10-19-2017)were not documented on the <br /> 10-27-2017 inspection report. <br /> -L9 alarm (occurred on 12-27-2017), L17 alarm (occurred on 12-27-2017), L21 alarm (occurred on 12-27-2017), <br /> L22 alarm (occurred on 12-27-2017), and L25 alarm (occurred on 1-16-2018)were not documented on the <br /> 1-25-2018 inspection report. <br /> -L25 alarm (occurred on 2-1-2018)was not documented on the 2-28-2018 inspection report, also, the alarm history <br /> print out attached to this inspection report appeared to be in a different language and was not legible. <br /> -L1 alarm (occurred on 3-28-2018)was not documented on the 3-28-2018 or the 4-26-2018 inspection reports. <br /> During the monthly inspection, the designated operator shall review the alarm history for the previous month, check <br /> that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br /> documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br /> monthly inspections at this facility are including all of the required information on the reports. Submit proof of <br /> correction to the EHD. <br /> This is a repeat violation, Class II. <br /> FA0003829 PR0232352 SCO01 06/20/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 4 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.