Laserfiche WebLink
SA N J O A Q Ut I N Environmental Health Department <br /> --CCUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> VANCO TRUCK-AUTO PLAZA 1033 W CHARTER WAY, STOCKTON June 20, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 320 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements. <br /> The ATG annunciator ,he sound alarm corrpor.er:t) us--d as the ci elf:ll p.evention systen,we-is riot functional for all <br /> onsite USTs at the time of testing, the light on the overfill alarm wor-Ked at the time of testing. The annunciator wiring <br /> was repaired and retested during the inspection with passing results. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> Overall Inspection ComiTients: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD \vitn a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by 7-20-2018 <br /> The correct positioning of the diesel T1 annular sensor couldn't be verified prior to the sensor removal. The <br /> following annular sensor (wrap around) cord lengths were measured today: <br /> 91/100 octane (10,000 gallon tank)- 217" <br /> 87 octane (12,000 gallon tank) - 214" <br /> diesel tanks (20,000 gallon tanks) -252" <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Lette-from Chief Financial Officer (if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable. can be stored at the facility or uploaded into CERS. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS <br /> FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: June 20, 2018 Inspector: Inspector Phone: <br /> Printed Name and Title: ELENA MANZO. Lead Senior REHS (209) 953-7699 <br /> Mike Boparai, Owner <br /> FA0013829 PR0232352 SCO01 06/20/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 6 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 I T 209 468-3420 1 F 209 464-0138 1 ww+w.sjcehd.com <br />