Laserfiche WebLink
SAN ;1 OAQ U I N Environmental Health Department <br /> --COUNT <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: 7Facility'Address: Date: <br /> VANCO TRUCK-AUTO PLAZA 33 W CHARTER WAY, STOCKTON June 20, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 211 CCR 2715(f)(2) Designated operator employee training not performed or log not kept. <br /> The designated operator employee trainirg log was no:onsite at the t,me of inspection. `o� designated operator shall <br /> train facility employees for which he or she is responsible in the proper operation and maintenance of the UST <br /> system once every 12 months. The training shall include, but is not limited to. <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitcriny equipment as specified iri the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified it the facility's response plan <br /> 4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br /> A copy of the training log was emailed to the facility by the DO representative at the time of inspection. Ensure that <br /> employees have beer trained by the designated operator and maintain the training list on site. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 307 CCR 2631(g), 2632(c) Monitoring system of the interstitial space of a double walled system not maintained. <br /> The diesel T1 annular sensor (wrap around sensor) rope broke at the time of its removal from the tank annular and <br /> couldn't be re installed at the time of inspection, therefore. the tank is not being monitored. The interstitial space shall <br /> be monitored with a monitoring system connected to an audible and visna! alarm system. Immediately contact a <br /> properly licensed: trained. and certified contractor to replace the failed component with a functional component (LG <br /> 113-x listed, if applicable) under permit and inspection of the EHD within one business day; as required. <br /> This is a repeat violation, Class II. <br /> 315 HSC 25291(e)Water in secondary containment not removed, analyzed, and properly disposed of (pre-Jul 2003). <br /> Liquid was observed in the T2 diesel STP sump (<1 cup), and in UDC Sat 14 and UDC 15/16 (unknown amount) . If <br /> water could enter into tiie secondary containment by precipitation cr infiltration. it must be rernoved and disposed of <br /> properly. The servica technician removed liquid obseved in the STF sump at the time of inspection. Ensure that all <br /> sumps and annular spaces are maintained free of liquid. <br /> Provide proof of correction that liquid was also removed from UDC Sat 14 and UDC 15/16. <br /> This is a repeat violation, Class II. <br /> 319 CCR 2635(b) No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty. <br /> The 87 octane, the T1 north diesel, and the T2 south dlesel spill contUiners (located in monitored sumps)failed the <br /> hydrostatic testing. and as such the 5-gallon capacity was also not verified, as such these US Ts are not equipped <br /> with functional spill containers. All LISTS shall be equipped with a spill container that has a minimum capacity of five <br /> gallons and a drain valve that allows drainage of the collected spill into the primary container or provide a means to <br /> keep the container empty. Immediately contact a properly licensed, trained, and certified contractor to install an <br /> approved spill container under permit and inspection of the EHD. as required. <br /> This is a repeat violation Class ll. <br /> FA0003829 PR0232352 SCO01 06/20/2018 <br /> EHD 23-01 Rev.10/31/2017 Page S of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-34201 F 209 464-0138 1 wvvw.sjcehd.com <br />