My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003 - 2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
610
>
2300 - Underground Storage Tank Program
>
PR0521866
>
COMPLIANCE INFO_2003 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2021 3:49:10 PM
Creation date
11/2/2018 5:10:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003 - 2007
RECORD_ID
PR0521866
PE
2371
FACILITY_ID
FA0014852
FACILITY_NAME
RANCHO SAN MIGUEL MARKET*
STREET_NUMBER
610
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
04745039
CURRENT_STATUS
01
SITE_LOCATION
610 S Cherokee Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\wng
Supplemental fields
FilePath
\MIGRATIONS\C\CHEROKEE\612\PR0521866\COMPLIANCE INFO 2003 - 2007 .PDF
QuestysFileName
COMPLIANCE INFO 2003 - 2007
QuestysRecordDate
10/28/2016 6:58:12 PM
QuestysRecordID
3244411
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
125
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 <br /> 1i 1► Page 6 of7 <br /> S. F X RISER COINTAWMIENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps 0 <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: 0 Sump Mamdhcturer X Industry Standard ❑Professional Engineer <br /> ❑Other(Spec6 <br /> Test Method Used: U Pressure ❑Vacuum X Hydrostatic <br /> ❑Other(Sp¢c ) <br /> Test Equi out Used:Incan TS STS Equipment Resolution: <br /> Fill Sump#81 Fill Sump 091 Fill Sump# Fill Sam # <br /> Sump Diameter: 42" 42" <br /> Sum 48" 48" <br /> Height from Tank Top to Top of IT, 12" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 18" 18" <br /> Electrical Penetration: <br /> Condition of sump prior to Clean Clean <br /> ttsti <br /> Portion of Stum Tested Full Full <br /> StM Material: Fiberglass Fiberglass <br /> Waft time betwecn applying 10 minutes 10 minutes <br /> pressure/vacmmr/water and <br /> starting test: <br /> Test Start Time: 8:55 am 8:55 am <br /> lydtW Reading.OV. 4.6"77 3.2232" <br /> Test End Time: 9:10 ani 9:10 am <br /> Final Readin (R,): 4-6501' 3.2253" <br /> Test Duration: 15 Minutes 15 Minutes <br /> Change in Re {RF-R; : +.0014' +.0021" <br /> Pass/Fail Threshold or Criteria: _.002"=pass <.O02'=VMS <br /> Test ResuNt X Pass Oren X Paas 0 Fail 0 Pass 0 fall 0 Pass ❑Fail <br /> Is there a sensor in the Sump? X Yes d No X Yes ❑No 0 Yes 0 No ❑Yes ONO <br /> Does the sensor alarm when <br /> eithcr product or water is XYes ❑No [INA XYes ❑No ❑NA O Yes ❑No [INA C Yes 0 No [INA <br /> detected? <br /> Was sensor temoved for testing? XYes 0 No DNA XYes 0 No DNA ❑Yea 0 No [INA GYes ❑No 0 NA <br /> Was sensor properly replaced and XYes 0 No ❑NA XYes ❑No ❑NA 0 Yes ❑No ❑NA 0 Yes 0 No [INA <br /> verified functional after testis ? <br /> Comments—(Include information on repairs madd prior to testing,attd rc mended follow-up forfaded tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.