My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
610
>
2300 - Underground Storage Tank Program
>
PR0521866
>
COMPLIANCE INFO_2016 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2021 3:49:10 PM
Creation date
11/2/2018 5:12:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2017
RECORD_ID
PR0521866
PE
2371
FACILITY_ID
FA0014852
FACILITY_NAME
RANCHO SAN MIGUEL MARKET*
STREET_NUMBER
610
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
04745039
CURRENT_STATUS
01
SITE_LOCATION
610 S Cherokee Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\wng
Supplemental fields
FilePath
\MIGRATIONS\C\CHEROKEE\612\PR0521866\COMPLIANCE INFO 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
11/1/2016 3:06:35 PM
QuestysRecordID
3247087
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
158
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> RANCHO SAN MIGUEL MARKET* 612 S Cherokee Ln, Lodi October 17, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. In the monitoring plan for TA0515700,the <br /> monitoring panel was listed as TLS 350 however it was observed as TLS 350 plus.The section labeled"Under <br /> Dispenser Containment(UDC)monitoring", labeled"UDC Secondary Containment Monitoring,"is as marked liquid, <br /> it should be marked none. No interstitial secondary monitoring was observed at the under dispenser containment on <br /> site.The section labeled personnel responsibilities showing Edgar Tracy and Casey Paoletti,should be update <br /> according to Mr. Jesus Jurado as they are no longer with the company. Monitoring plan stated daily visual piping <br /> inspections are being conducted however Mr.Jesus Jurado stated that the site is doing daily air quality related <br /> inspections and not daily visual piping inspections. <br /> The monitoring plan for TA0515701,the monitoring panel is listed TLS 350, however, it is observed TLS 350 plus. <br /> The section labeled personnel responsibilities showing Edgar Tracy and Casey Paoletti, should be update according <br /> to Mr. Jesus Jurado as they are no longer with the company. The monitoring plan must be uploaded to the <br /> California Environmental Reporting System(CERS). Immediately log into CERS, make the necessary changes, <br /> and submit for review by the EHD. Monitoring plan stated daily visual piping inspections are being conducted <br /> however Mr.Jesus Jurado stated that the site is doing daily air quality related inspections and daily visual piping <br /> inspections. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 107 CCR 2632(d)(1)(C)Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted.The site plan is lacking leak detector locations, piping <br /> layout,and the location of the 87 and 91 split tanks are not accurately depicted.The location of the split tanks are <br /> reversed A site plan must be submitted identifying the locations where monitoring will be performed. Immediately <br /> log into the California Environmental Reporting System(CERS)at http://cers.calepa.ca.gov/and upload a copy of <br /> the UST Monitoring Site Plan. <br /> This is a repeat violation,Class II. <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> Accurate monitoring records for the last three years were not found on site. The recent Secondary Containment <br /> Testing results located on site for testing conducted on 8/26/16 was not accurate as the date marked on the testing <br /> report was marked as 8/26/2016 and 9/22/2016. Accurate dates must be written.The reviewed monitoring plan <br /> indicated that the annual tank integrity testing(23 CCR 2643.1)were conducted however results were not found on <br /> site.These records shall be maintained on site for at least three years. Monitoring records include: (1)date and <br /> time of all monitoring or sampling; (2)monitoring equipment calibration and maintenance records;(3)results of any <br /> visual observations; (4)results of sample analysis performed a lab or in the field; (5)logs of all readings of gauges <br /> or other monitoring equipment,ground water elevations, or other test results;(6)results of inventory readings and <br /> reconciliations. Immediately locate the accurate Secondary Containment Testing results and submit a copy to the <br /> EHD. <br /> This is a Class II violation. <br /> FAC014852 PR0521066 SCO01 10117/2017 <br /> EHD 23-01 Rev.09122116 Page 4 of 6 underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.