2300 - Underground Storage Tank Program
>
PR0231066
>
COMPLIANCE INFO_2016 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:24 AM
Creation date
11/2/2018 6:07:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2017
RECORD_ID
PR0231066
PE
2361
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CORONADO\3807\PR0231066\COMPLIANCE INFO 2016 - PRESENT.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank Program Inspection Report Item#104 <br /> CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> Noted as"corrected on site." <br /> Underground Storage Tank Program Inspection Report Item#105 <br /> CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br /> The information and corrections requested have been submitted in CERS. <br /> Underground Storage Tank Program Inspection Report Item#107 <br /> CCR 2632(d)(1)(C)Plot plan/site map not submitted or failed to completely show where monitoring is <br /> performed. <br /> The updated site plan submitted in CERS includes this information. <br /> Underground Storage Tank Program Inspection Report Item#201 <br /> CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> The two missing records are included with this response. A thorough audit of onsite records determined <br /> that an additional required service record was not available during the inspection. That record is also <br /> included. All three have been sent to the facility. <br /> Underground Storage Tank Program Inspection Report Item#204 <br /> CCR 2712(1) Current monitoring plan approved by the EHD not found on site. <br /> A copy of the plan has been sent to the site. <br /> Underground Storage Tank Program Inspection Report Item#204 <br /> CCR 2712(1) Failure to have an approved UST response plan available onsite. <br /> A copy of the plan has been sent to the site. <br /> Underground Storage Tank Program Inspection Report Item#206 <br /> CCR 2712 Failure to comply with UST operating permit conditions. <br /> The permit was posted on a bulletin board in the site's administration area on 11/16/17. <br /> Underground Storage Tank Program Inspection Report Item#207 <br /> HSC 25294 Failed to record unauthorized release from primary containment. <br /> Anecdotal information about the site indicates that the staining on the floor in the Day Tank Room is <br /> over 12 years old with no change in size since then. The stained areas were dry and covered with dust <br /> and cobwebs during my visit last week. A small area of oily residue was found when touching three pipe <br /> junctions. <br /> Our contractor, Bill Rogers of Jauregui &Culver, Inc., is working with you to make repairs to the piping. <br /> This is not a point of hazardous waste generation but we agree that repairs should (and are) being <br /> made. <br /> Underground Storage Tank Program Inspection Report Item#211 <br /> CCR 2715(0 Designated operator employee training not performed or log not kept. <br /> A secondary employee, Ron Williams, was trained by the designated operator on 11/14/17. Ron is the <br /> alternate and night shift technician. His training record is included with this response. <br /> Kenneth Carr's training information is also included. His record was in the site's UST binder at the time <br /> of inspection. <br /> Underground Storage Tank Program Inspection Report Item#214 <br /> HSC 25281.5(b)(3) Unburied emergency generator fuel piping not visually inspected at least monthly or <br /> log kept. <br /> A clipboard with a log was in use to inspect the unburied piping during my visit. Inspections conducted <br /> during generator runs will be logged going forward. <br />