Laserfiche WebLink
Appendix VI <br /> (Copies of Monitoring System Certification forth and UST Monitoring Plot Plan available at http,Uyvww_waterboards.ca.ggy) <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use Ely All Jurisdictions Within the State of California <br /> Authority Cited. Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br /> The ownertoperator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name:SPRINT STOCKTON Bldg.No.: <br /> Site Address: 3807 CORONADO AVE City:STOCKTON zip:95204 <br /> Facility Contact Person:KEN CARR Contact Phone No.:(209)937-5800 <br /> Make/Model of Monitoring System:VEEDER ROOT TLS 3000 Date of Testing/Servicing: 11/1812010 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspectediserviced: <br /> ank ID:EMERGENCY GENERATOR,DIESEL AST 5,000 GAL ank ID: <br /> In-Tank Gauging Probe. Model:MAG i M In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor, Model:794390.420 M Annular Space or Vault Sensor. Model: <br /> ✓ Piping Sump/Trench Sensor(s), Model:794380-208 M Piping Sump i Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: [ Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: M Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: ® Electronic Line Leak Detector. Model: <br /> J Tank Overfill i High-Level Sensor. Model:VIR Ext Alarm&Flapper M Tank Overfill 1 High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on Page 2). x Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID:EMERGENCY GENERATOR,DIESEL UST 10,000 GAL Tank ID: <br /> f In-Tank Gauging Probe. Model:MAG 1 M In-Tank Gauging Probe. Model: <br /> J Annular Space or Vault Sensor. Model:794380-302(BRINE) »Annular Space or Vault Sensor. Model: <br /> J Piping Sump l Trench Sensor(s). Model:194380-208 M Piping Sump l Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: M Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: ® Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: ® Electronic Line Leak Detector. Model: <br /> J Tank Overfill l High-Level Sensor. Model:V/R Ext Alarm&Flapper x Tank Overfill I High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on Page 2). it Other(specify equipment t pe and model in Section E on Page 2). <br /> Dispenser ID: Dispenser 10: <br /> Lw] Dispenser Containment Sensor(s). Model: M Dispenser Containment Sensor(s). Model: <br /> Ei(I Shear Valve(s). M Shear Valve(s). <br /> x Dispenser Containment Floats and Chain(s). x Dispenser Containment Float(s)and Chain(s). <br /> ispenser ID: Ispenser ID: <br /> u Dispenser Containment Sensor(s). Model: M Dispenser Containment Sensor(s). Model: <br /> M Shear Valve(s). M Shear Valve(s). <br /> u Dispenser Containment Float(s)and Chain(s). x Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> M Dispenser Containment Sensor(s). Model: ® Dispenser Containment Sensor(s). Model: <br /> M Shear Valve(s), U Shear Valve(s). <br /> v Dispenser Containment Floats)and Chain(s )fl Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was Inspectediserviced In accordance with the manufacturer's' <br /> guidelines. Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verity that this information is correct and a <br /> Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the <br /> report;(check ail that apply): I System set-up I Alarm history report <br /> e_-,,�'462 <br /> Technician Name(print): Rene LeiMesnager Signature. <br /> Certification No.: A26748 License.No.:203029 <br /> Testing Company Name:LeMesnager Engineering Inc ¢p <br /> Testing Company Address: 9450 B Mira Mesa Blvd_PMB 229,San Diego,CA 92126 Date of Test riglServicing:11/18/2010 <br /> Monitoring System Certification <br /> Page,of. N O v 3 0 2010 <br /> SAW JOAOLy*:COUNr( <br /> E,W RONIM'SO T AL <br /> I EI,Ulri ISL?A.RTMENT <br />