My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2725
>
2300 - Underground Storage Tank Program
>
PR0231073
>
COMPLIANCE INFO 2008-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2024 1:34:02 PM
Creation date
11/2/2018 6:36:22 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2012
RECORD_ID
PR0231073
PE
2361
FACILITY_ID
FA0002064
FACILITY_NAME
7-ELEVEN INC. STORE #14117
STREET_NUMBER
2725
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
02
SITE_LOCATION
2725 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\COUNTRY CLUB\2725\PR0231073\COMPLIANCE INFO 2008-2012.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
402
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page I of 1 <br /> 6.PIPING SUMP TESTING <br /> 'rest Method Developed By: Tank Manufacturer Industry Standard r Professional Engineer <br /> r Other(Specify) <br /> Test Method Used By: r Pressure r Vacuum P Hydrostatic <br /> r Other(Spec) <br /> Test Equipment Used:VPLT Equipment Resolution:0.00001 in. <br /> STP Containment for STP Containment for <br /> Tank 1 pul- 1 Tank <br /> Sump Diameter/Dimensions: 48 in. 48 in. in. in. <br /> Sump Depth: 30.00 in. 30.00 in. in. in. <br /> Sump Material: Fiberglass Fiberglass <br /> Height from Tank Top to Top of 9.00 16.00 <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 3.00 3.00 <br /> Electrical Penetration: <br /> Condition of sump prior to testing: good good <br /> Portion of Sump Tested' I l 18 <br /> Does turbine shut down when <br /> sump sensor detects liquid(both C Year Nor NA C' Yes r Nor NA r Yes r Nor NA r Yes r, Nor NA <br /> product and water)?* <br /> Turbine shutdown response time 02:00:00 sec 02:00:00 sec sec sec <br /> Is system programmed for fail-safe 0 Yes r Nor NA r Yes r Nor NA r Yes r Nor NA r Year Nor NA <br /> shutdown?" <br /> Was fail-safe verified to be r* Yes r Nor NA re Yes r Nor NA r Yes r Nor NA r Yes r No r NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5 min 5 min min min <br /> test <br /> Test Start Time: 10:47:00 10:47:00 <br /> Initial Reading(RI): 0.00000 in. 0.00000 in. <br /> Test End Time: 11:17:00 11:17:00 <br /> Final Reading(RF): -0.00160 in. -0.00160 in. <br /> Test Duration: 30 min 30 min <br /> Change in Reading(RF-RI): -0.00160 in. -0.00160 in. <br /> Pass/Fail Threshold or Criteria: +/-0.00200 +/-0.00200 +/- +/- <br /> Test Result: Pass Pass <br /> Was sensor removed for testing? G Yes r No r NA G Yes r No r NA r Yes r Nor NA r Yes r Nor NA <br /> Was sensor properly replaced and ro Yes r Nor NA ro Yes r Nor NA r Yes r No r NA r Yes r Nor NA <br /> verified functional after testing? <br /> Comments?(include information on repairs made prior to testing,and recommended follow-up for failed rests) <br /> 'If the entire depth of the sump is not tested,specify how much was tested.If the answer to any of the questions indicated with an asterisk(-)is"NO"or"NA",the entire sump <br /> must be tested. <br />
The URL can be used to link to this page
Your browser does not support the video tag.