MONITCWING SYSTEM CERTI ATION <br /> CERTIFICATION 1 TEST DATE: January 8, 2008 <br /> Al. FACILITY A2. OWNER <br /> Name 7-Eleven Market#23681 Store#14117 Name 7-Eleven, Inc <br /> Address 2725 Country Club Lane,Stockton,CA 95201 Address P.O. Box 711, Dallas,TX 75221 <br /> Phone# 209-463-1259 Phone# 805-523-2949 <br /> Contact Jay Stemley Contact Shane Partridge <br /> D. RESULTS OF TESTING/ SERVICING <br /> Make ! Model of Monitoring System: Veeder-Root TLS-350 <br /> Software Version Installed: 327.04 <br /> Complete the following checklist: <br /> Yes ❑ No* Is the audible alarm operational? <br /> ■ Yes ❑ No* Is th�allsensors <br /> alarm operational? <br /> ■ Yes ❑ No* Were visually inspected,functionally tested,and confirmed operational? <br /> Yes No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br /> will not interfere with their proper operation? <br /> ❑ Yes HE If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modems) <br /> operational? <br /> ■ Yes For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate <br /> positive shutdown? (check all that apply) ■ Sump/Trench sensors; ■ Dispenser Containment Sensors. <br /> ■ Yes ❑ No* Did you confirm positive shut-down due to leaks and sensor failureldisconnection? <br /> ❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no <br /> ■ NIA mechanical overfill prevention valve is installed),is the overfill warning alarm visible and audible at the tank <br /> fill points)and operating properly? If so,at what percent of tank capacity does the alarm trigger? <br /> El Yes' ■ No Was any monitoring equipment replaced? If yes,identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> 0 Yes* ■ No Was any liquid found inside any secondary containment systems designed as dry systems? <br /> (Check all that apply) ❑ Product; ❑ Water. If yes,describe causes in Section E,below. <br /> ■ Yes ❑ No* Was monitoring system set-up reviewed to insure proper settings? Attach set-up reports,If applicable. <br /> ■ Yes ❑ No* FIs all monitoring equipment operational per manufacturer's specifications? <br /> * In Section E below, describe how and when these deficiencies were or will be corrected. <br /> E. COMMENTS <br /> This site has a remote overfill alarm as well as a mechanical overfill. The remote overfill alarm is inoperative. <br /> 02006 Walton Engineering,Inc. <br /> Page 2of3 <br />