My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2001 - 2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORONADO
>
3807
>
2300 - Underground Storage Tank Program
>
PR0231066
>
COMPLIANCE INFO 2001 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:22 AM
Creation date
11/2/2018 7:33:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001 - 2009
RECORD_ID
PR0231066
PE
2361
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\C\CORONADO\3807\PR0231066\COMPLIANCE INFO 2001 - 2009.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing <br /> Software Version Installed: 421.00 <br /> Complete the following checklist: <br /> ®Yes ❑No* Is the audible alarm operational? <br /> ®Yes ❑No* Is the visual alarm operational? <br /> ®Yes ❑No* Were all sensors visually inspected,functionally tested, and confirmed operational? <br /> M Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other <br /> equipment will not interfere with their proper operation? <br /> E0 Yes ❑ NA <br /> [I No If alarms are relayed to a remote monitoring station, is all communications equipment(e.g. modem)operational? <br /> ❑Yes For pressurized piping systems, does the turbine automatically shut down if the piping secondarycontainment <br /> ❑ No monitoring system detects a leak,fails to operate, or is electrically disconnected? If ves:which sensors initiate <br /> ®NA positive shut down? (Check all that apply) ❑Sump/Trench Sensors ❑Dispenser Containment Sensors ❑ I <br /> Did you confirm positive shutdown due to leaks and sensor tailure/disconnection'e ❑Yes ❑No <br /> 59 Yes ❑ NA For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e. no <br /> ❑ No mechanical overfill prevention valve is installed), is the over-fill warning alarm visible and audible at the tank <br /> ill point(s)and operating properly? If yes, at shat percent of tank capacity doe the alarm trigger? % <br /> ❑Yes H No as any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E, below. <br /> ❑Yes ®No Was liquid found inside any secondary containment systems designed as dry systems?(Check all that apply) <br /> ❑Product ❑Water If yes, describe causes in Section E, below. <br /> ®Yes ❑No Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br /> ®Yes ❑ No* Is all monitoring equipment operational per manufacturer's specifications? <br /> * In Section E below,describe how and when these deficiencies were or will be corrected: <br /> E. Comments. <br /> Cite has remote mnnitnrinsz (monitored by BMF)- <br /> Monitoring System Certification Page 2 of 3 3101 <br />