My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2001 - 2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORONADO
>
3807
>
2300 - Underground Storage Tank Program
>
PR0231066
>
COMPLIANCE INFO 2001 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:22 AM
Creation date
11/2/2018 7:33:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001 - 2009
RECORD_ID
PR0231066
PE
2361
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\C\CORONADO\3807\PR0231066\COMPLIANCE INFO 2001 - 2009.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r • • <br /> D. Results of Testing/Servicing <br /> Software Version Installed: 421 <br /> Complete the following checklist: <br /> J Yes No' Is the audible alarm operational? <br /> ✓ Yes No* Its the visual alarm operational? <br /> J Yes No' ere all sensors visually inspected,fractionally tested,and confirmed operational? <br /> J Yes No' Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their <br /> proper o erstlon? <br /> J Yes No* If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? <br /> N/A <br /> Yes No' For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system <br /> J WA detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate positive shut-down? (Check all the <br /> apply) M Sump/Trench Sensors; M Dispenser Containment Sensors.Did you confirm positive shutdown due to leaks and sensor <br /> failure/disconnection? v Yes; x No. <br /> Yes No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no mechanical overfill prevention <br /> J WA valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s)and operating property? If so, at who <br /> ercent of tank capacity does the alarm Wager? 90 <br /> Yes' ✓ No as any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the <br /> manufacturer name and model for all replacement parts in Section E,below. <br /> Yes' ✓ No as liquid found inside any secondary containment systems designed as dry systems? (Check all that apply)®Product; Mw Water. <br /> If es,describe causes in Section E,below. <br /> ! Yes No' as monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> ! Yes No' Is all monitoring equipment operational per manufacturer's specifications? <br /> In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: The sensors were tested and BME confirmed seeing the alarms remotely. <br /> Monitoring System Certification Page 2 of 4 12/07 <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.