My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2001 - 2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORONADO
>
3807
>
2300 - Underground Storage Tank Program
>
PR0231066
>
COMPLIANCE INFO 2001 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:22 AM
Creation date
11/2/2018 7:33:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001 - 2009
RECORD_ID
PR0231066
PE
2361
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\C\CORONADO\3807\PR0231066\COMPLIANCE INFO 2001 - 2009.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 • <br /> AST Aboveground Storage Tank for diesel generator ftiel. Tank aboveground <br /> Participants <br /> A BMC engineer will be at the BMC control center guiding and overseeing the work. <br /> The BMC engineer will have complete authority to accept or reject testing results. <br /> As often as possible the FAS will perform the field inspection, testing and <br /> calibration of control points and alarms. <br /> Electricians will be required to disassemble high voltage electrical panels and perform <br /> high voltage testing. <br /> Generator technicians may be required to troubleshoot generator-related problems. <br /> UPS vendor may be required to troubleshoot UPS related problems. <br /> Fire alarm systems vendor may be required to troubleshoot Halon, fire alarm and Vesda <br /> related problems. <br /> Time Work to be Performed <br /> The revalidation will be performed during normal working hours. <br /> Where work involves normal accepted Sprint practices and requirements for after hour <br /> jeopardy work those guidelines will be followed. <br /> Examples of after hours jeopardy work would include work being performed in electrical <br /> panels, operation of a generator where building power load would be transferred to the <br /> generator. <br /> .Any work needing to be done over and around switching equipment that could result in <br /> damage occurring to equipment, etc. <br /> Space Temperatures <br /> The FAS will take the space temperature and verify reading at BMC. The FAS will then <br /> slowly elevate the area around the sensor using a hot air device such as a blow dryer. <br /> The BMC will then verify temperature alarms at the various temperature alarm levels. <br /> If a sensor is within 5 degrees of field reading then it may be software calibrated. <br /> If it is not within 5 degrees or does not respond to surrounding temperature change then it <br /> will be replaced. <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.