My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2001 - 2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORONADO
>
3807
>
2300 - Underground Storage Tank Program
>
PR0231066
>
COMPLIANCE INFO 2001 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:22 AM
Creation date
11/2/2018 7:33:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001 - 2009
RECORD_ID
PR0231066
PE
2361
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\C\CORONADO\3807\PR0231066\COMPLIANCE INFO 2001 - 2009.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(3) Inspecting for the presence of hazardous substance, water, or debris in under- <br /> dispenser containment areas, and checking that the monitoring equipment in <br /> these areas is located in the proper position to detect a leak at the earliest <br /> possible opportunity. <br /> (4) Inspecting for the presence of hazardous substance, water, or debris in <br /> containment sumps that, in the past month, have had an alarm for which there is <br /> no record of a service visit, and checking that the monitoring equipment in these <br /> containment sumps is located in the proper position to detect a leak at the <br /> earliest possible opportunity. <br /> (5) Checking that all required testing and maintenance for the underground storage <br /> tank system have been completed, and documenting the dates these activities <br /> occurred. <br /> (6) Verifying that all facility employees have been trained in accordance with <br /> subdivision 2715(f). <br /> (d) The designated UST operator(s) shall provide the owner or operator with a copy of <br /> each monthly inspection report, and alert the owner or operator of any condition <br /> discovered during the monthly visual inspection that may require follow-up actions. <br /> (e) The owner or operator shall maintain a copy of the monthly inspection record and all <br /> attachments for the previous twelve months. The records shall be maintained on-site <br /> or, if approved by the local agency, off-site at a readily available location. <br /> 4 No designated operator monthly inspection reports were found on site at the <br /> time of the October 30, 2007, routine UST inspection. <br /> Title 23, CCR 2715 (f) Designated operator: employee training. By July 1, 2005, <br /> and every twelve months thereafter, the designated UST operator(s) shall train facility <br /> employees for which he or she is responsible in the proper operation and maintenance <br /> of the underground storage tank system. For facility employees hired on or after July 1, <br /> 2005, the initial training shall be conducted within 30 days of the date of hire. <br /> (1)The training for facility employees must include, but is not limited to: <br /> (A) The operation of the underground storage tank system in a manner consistent <br /> with the facility's best management practices. <br /> (B) The facility employee's role with regard to the monitoring equipment as specified <br /> in the facility's monitoring plan. <br /> (C) The facility employee's role with regard to spills and overfills as specified in the <br /> facility's response plan. <br /> (D) The name of the contact person(s) for emergencies and monitoring equipment <br /> alarms. <br /> (2) At least one of the facility employees present during operating hours shall have <br /> current training in accordance with subdivision (f)(1). For facilities that are not <br /> routinely staffed, the designated UST operator shall implement a facility employee <br /> training program approved by the local agency. <br /> (3) A list of facility employees who have been trained by the designated UST operator(s), <br /> shall be maintained on-site or off-site at a readily available location, if approved by <br /> the local agency. The list shall be provided to the local agency upon request. The list <br /> shall include the dates of training for all facility employees, and the hiring dates for all <br /> facility employees hired on or after July 1, 2005. <br /> -> During the September 28, 2005, routine UST inspection, only one employee had <br /> been trained by the designated operator. This facility operates 24 hours daily and <br /> this employee is not present at all times. <br /> 8 <br />