My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2001 - 2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORONADO
>
3807
>
2300 - Underground Storage Tank Program
>
PR0231066
>
COMPLIANCE INFO 2001 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:22 AM
Creation date
11/2/2018 7:33:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001 - 2009
RECORD_ID
PR0231066
PE
2361
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\C\CORONADO\3807\PR0231066\COMPLIANCE INFO 2001 - 2009.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. SWRCB,Jenuary,2002 . � Page of <br /> -� 7. UNDER-DISPENSER CONTAINMENT(UDC)TESTING Job#: T7029132 <br /> Test Method Developed By: ❑UDC Manufacturer ❑ Industn'Standard ❑ Professional Engineer <br /> ®Other(Specify) <br /> Test Method Used: ❑[]Pressure ❑o Vacuum ❑M Hydrostatic <br /> pother fSpeci fyl <br /> Test Equipment Used: Equipment Resolution: <br /> UDC# UDC# UDC# UDC# <br /> UDC Manufacturer: <br /> UDC Material: <br /> UDC Depth: <br /> Heighrt fromUDC Bottomto Top <br /> of Highest Piping Penetration: <br /> Height from IJDC Bottom to <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> testing: <br /> Portion of UDC Tested <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes ❑No ❑1'l'°` ❑yes ❑NO ❑NA El yes ❑No ❑NA C]Yes ❑No ❑NA <br /> product and water)?' <br /> Turbine shutdo,"m response time <br /> Is systemiprogrammed for fail- ❑Yes ❑No ❑NA ❑Yes ❑No [3 NA ❑Yes ❑No [INA ❑Yes ❑No ❑NA <br /> e shutdown? <br /> fail-safe verified to be ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> ratiomr* <br /> Wait time beN een applying <br /> pressureh°acuuminater and <br /> starting test <br /> Test Start Tim: <br /> Initial Reading(Rj): <br /> Test End Time: <br /> Final Reading(RF): <br /> Test Duration: <br /> Change in Reading{RF--Rr}: <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: ]Vass []Foal` t [ _Pass Q �atr Pss .;Fst Fait <br /> Was sensor removed for testiyes ❑No d NA ❑Yes ❑No ❑NA a Yes ❑ No 11NA ❑Yes ❑ala ❑NA <br /> mng? ❑ <br /> Was sensor properly replaced and NO <br /> verified functional after testing? ❑Yes 11 ❑ Oyes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑hb ❑NA <br /> Comments—(include information on repairs made prior to testing,and recoriimertdM follolr-up.for failed tests) <br /> NIA <br /> �he entire depth of the UDC is not tested.specify how much was tested. If the answer to any of the questions indicated with an asterisk <br /> jS"110' ar'`NA',the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.