My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2001 - 2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORONADO
>
3807
>
2300 - Underground Storage Tank Program
>
PR0231066
>
COMPLIANCE INFO 2001 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:22 AM
Creation date
11/2/2018 7:33:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001 - 2009
RECORD_ID
PR0231066
PE
2361
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\C\CORONADO\3807\PR0231066\COMPLIANCE INFO 2001 - 2009.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r SWRCB Japuary,2002 Page of <br /> 6. PIPING SUMP TESTING Job#: T7029132 <br /> Test Method Developer)By: n Sump Manufacturer 01ndustn.Standard 0 Professional Engineer <br /> p Other(Speei fi,) <br /> ` - est Method Used: ❑©Pressure Q Vact'um FNJ Hydrostatic <br /> ❑ Other(Specif})) <br /> Test Equipment Used: Incon TS-STS Equipment Resohition: +1-0.002 Inches <br /> Sump# 1 Sump# Sump# Sump# <br /> Sump Diameter; 44" <br /> Sump Depth: 50" <br /> Sump Material: FRP <br /> Height from Tank Top to Top of 2011 <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 60« <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Good <br /> Portion of Sump Tested' 2"above pipe <br /> Does turbine shirt down when <br /> sump sensor detects liquid(both ❑Yes ❑No ®NA D Yes ElNo ❑NA ❑Yes ❑No a NA ❑Yes ElNo O'NA <br /> product and ivater)?. <br /> Turbine shutdown response time NIA <br /> Is system programmed for fail-safe ❑Yes ❑No IM NA D Yes ❑No ❑NA ❑Yes. ❑No ❑NA ❑Yes ❑No ❑NA <br /> shutdown?* <br /> Was fail-sale verified to be ❑Yes ❑No ®NA Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No D NA <br /> o rational?' <br /> ait time between apptying <br /> essurehvactnira/later and starting 15 min <br /> est: <br /> Test Stait Time: 11:26am 111:41 am <br /> Initial Readnig(Rj): 5.231815.2329 <br /> Test End Time: 11:41am 111.56am <br /> Final Reading(RF): 5.231915.2319 <br /> Test Duration: 15 min. <br /> Change in Reading{RF-n: +0.00031-0.0010 <br /> Pass/Fail Threshold or Criteria: +1-0.002" <br /> Test Result: I$�Prix p Fel = 1?as �a,Q l^aE� Qass C��Fail ❑{'as4 QaFil � <br /> ...r"�i n_.. v V., _,.. .....n . _. .. .r . •e. r ... tir v. .. ..... ... n_. r..a......, -.i <br /> Was sensor removed for testing? Yes ❑No D NA Yes D No ❑NA I]Yes ❑No ❑NA ❑Yes ❑No ❑ NA <br /> Was sensor properly replaced and N Yes ❑No ❑NA DYes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> verified functional after testis 2 <br /> Comments—(include h?formation on repairs made prior to testing, and recoinmended follow7yp for.failed tests) <br /> he entire depth of the sump is not tested,specify how much was tested_ If the answer to=of the questions indicated with an <br /> WAisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.