My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
1427
>
2300 - Underground Storage Tank Program
>
PR0521942
>
COMPLIANCE INFO 2008-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 4:15:38 PM
Creation date
11/2/2018 8:03:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2015
RECORD_ID
PR0521942
PE
2371
FACILITY_ID
FA0014921
FACILITY_NAME
RANCHO SAN MIGUEL MARKET*
STREET_NUMBER
1427
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
16902016
CURRENT_STATUS
01
SITE_LOCATION
1427 S AIRPORT WAY
P_LOCATION
02
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\A\AIRPORT\1427\PR0521942\COMPLIANCE INFO 2008-2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
367
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OCT-25-2013 14:47 Service Station System 438 93B 3588 P.37 <br /> �0V <br /> 'FIJ <br /> 7. UNDER-DISPENSER CONTAINMENT(VDC)TESTING <br /> Test Method Developed By: L7 UDC Manufacturer M Industry Standard El Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used: ❑ Pressure ❑ Vacuum Hydrostat o <br /> ❑ Other(Spec) <br /> Test Equipment Used: Ineon Sump Tester Equipment Resolution: +1-4.002" <br /> UDC OJ 1/2 UDC#314 UDC#516 <br /> UDC Manufacturer: Environ Environ Environ <br /> UDC Material: Poly Poly Poly <br /> UDC De the 31" 31" 31" <br /> Height from UDC Bottom to Top 12" 17" _ 12" <br /> of Hi hest Piping Penetration: <br /> Height from UDC Bottom to 4" 4" b" <br /> Lowest Electrical Penetration? <br /> Condition of UDC prior to Good Good Good <br /> testing: <br /> Portion of UDC Tested 2"alcove Eipin8 2"above piping 2"above piping <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes [3 No ®NA ❑Yes ❑No 0 NA ❑Yes C]No M NA <br /> product and water)?* <br /> Turbine shutdown response time N/A N/A NIA <br /> Is system programmed for fail- d Yes ❑No 0 NA ❑Yes ❑No M NA p Yes❑No RNA <br /> safe shutdown?" <br /> Was fail-safe verified to be ❑Yes❑No Z NA <br /> operational?' <br /> (�Yes [I No 10 NA L] Yes[1 No ®NII <br /> Wait time between applying � <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes <br /> starting;test <br /> Test Start Time: 11:49 am 11.49 am 11:49 am <br /> Initial Readin R.[): 3.0719 1,5951 3.2148 <br /> Test End Time: 12:04 pm 12:04 pm 12:04 pm <br /> Final Reading{Rt); 3.0723 1.5939 3,2148 <br /> Test Duration: 15 min. 15 min. 15 min. <br /> Chane in Reading(RF-Ri): 0,0004 0,0012 None <br /> Pass/Fail Threshold or Criteria +/-0.00211 ' +1-0.00271 +/-0.002" <br /> Test Result: 1] Pass 0 Fail f Q Pass G Fail 0 Pass 0 Fail <br /> Was sensor removed for iesrin ? M Yes ❑No❑NA 123 Yes ❑No❑NA 1 p Yes M No❑NA <br /> Was sensor properly replaced and U Yes Q No❑NA E Yes p No❑NA [D Yes 0 No lI NA <br /> verified functional after testing? <br /> Comments— (include inforritarlor+on repairs made prior to testing, [trtcl recammendNdfollory-up fnr faller!rests) <br /> "Sensor functionality was not cunfirmed. This procedure is not part of the Secondary Containment testing scope of work". <br /> ' if the entire depth of the UDC is not tested,specify haw much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />