My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
1427
>
2300 - Underground Storage Tank Program
>
PR0521942
>
COMPLIANCE INFO 2008-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 4:15:38 PM
Creation date
11/2/2018 8:03:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2015
RECORD_ID
PR0521942
PE
2371
FACILITY_ID
FA0014921
FACILITY_NAME
RANCHO SAN MIGUEL MARKET*
STREET_NUMBER
1427
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
16902016
CURRENT_STATUS
01
SITE_LOCATION
1427 S AIRPORT WAY
P_LOCATION
02
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\A\AIRPORT\1427\PR0521942\COMPLIANCE INFO 2008-2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
367
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OCT-2S-2813 14:47 Service Station Syst.erns 488 538 8888 P.88 <br /> 0 * PECP1 /r= r- ) <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Rises Containment Sumps ❑ <br /> �, <br /> Fill Riser Containment Sumps are Present,but were Not,rested [I E <br /> Test Method Developed lay_ ❑ Sump Manufacturer ® Industry Standard ❑Pia i inrngincjer, � <br /> LJ Other(.Spaelfy) C <br /> Test Niethod Used: p Pressure p Vacuum Hydrostatic <br /> Q Other(Specify) <br /> Test Equipment Used: Incon Sump Tester Equipment Resolution: +/-0.002" <br /> Fill Sump N 87 Fill Sump#91 <br /> Surnp Diameter: 42" 42" <br /> SumDe the 69., 69" <br /> Height from Tank Top to'T'op of k 191, 191, ; <br /> Highest Pi in ..Penetration_ <br /> Height from Tank Top to Lowest 16„ 19" <br /> Electrical Penetration: <br /> Condition of sump prior to Good Good <br /> testing. <br /> Portion of Sump Tested 2„abovepiping_ 2"above pip4. , <br /> Sump Material: Fiberglass Fiberglass <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes <br /> starting test: <br /> Test Start Time: 8:14 am 8:19 ain <br /> Initial Readin (R1): 5.8986 5.7639 <br /> Test Lend Time: 8:34 am 8:34 ani <br /> Final Reading(RP): 5.8982 5.7637 <br /> Test Duration: 15 nein. 15 min. <br /> Change hi Readin RF-Rt): 0.0004 0.0002 <br /> Pass/Fail Threshold or Criteria: +40.00211 +l-0.002" <br /> Test Result: i ® Pass 0 Fail 0 Pass 0 Fail <br /> Is there a sensor in the SUME? ®Yes ❑No ®Yes ❑No <br /> Does the sensor alarm when -- <br /> either product or water is ❑ Yes p No 0 NA p Yes ❑No®NA <br /> detected? <br /> Was sensor removed for testing? N Yes El No ❑NA 0 Yes❑No E3 NA <br /> Was sensor properly replaced and <br /> verified functional after testing? ( Yes❑No ❑ NA ®Yes p No[ NA <br /> Comments—(include information ars repairs made prior to resting, and recommended Loflvw-y for failed tests} <br /> Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work <br /> TOTAL P.88 <br />
The URL can be used to link to this page
Your browser does not support the video tag.