My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2004-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
1427
>
2300 - Underground Storage Tank Program
>
PR0521942
>
COMPLIANCE INFO 2004-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 9:18:31 AM
Creation date
11/2/2018 8:12:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2007
RECORD_ID
PR0521942
PE
2371
FACILITY_ID
FA0014921
FACILITY_NAME
RANCHO SAN MIGUEL MARKET*
STREET_NUMBER
1427
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
16902016
CURRENT_STATUS
01
SITE_LOCATION
1427 S AIRPORT WAY
P_LOCATION
02
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\A\AIRPORT\1427\PR0521942\COMPLIANCE INFO 2004-2007.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 5 of 7 <br /> 7. UNDER-DISPENSER C©NT,A INAMNT C TESTING <br /> Test Method Developed By: 0 UDC Manufacturer X Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum X Hydrostatic <br /> ❑Other(Spec) <br /> JTest Equipment Used_ Incon TS STS Equipment Resolution: <br /> UDC#3d UDC 4 56 UDC# UDC# <br /> UDC Manufacturer: Environ Environ <br /> UDC Material: —Poly Poly <br /> UDC De the 33" 33„ <br /> Height from UDC Bottom.to Top 4" 4" <br /> of Highest P1pjK Penetration: <br /> Height from UDC Bottom to 15" 15" <br /> Lowest Electrical.Penetration: <br /> Condition of UDC prior to Clean Clean <br /> testing : <br /> Portion of UDC Tested Full Full <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both XYes ❑No ❑NA XYes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> product and water, f <br /> Turbine shutdown res once time 2 Seconds 2 Seconds <br /> is system programmed for fail- <br /> safe shutdown?0 XYes ❑No ❑NA XYes ❑No 0 NA ❑Yes ❑No ❑NA ❑Yes 0 No 1:NA <br /> Was fail-safe verified to be XYes ❑No ❑NA XYes ❑No ❑NA 17 Yes ❑No ❑NA ❑Yes ❑No LI NA <br /> o erational?" <br /> Wait time between applying 15 minutes 15 minutes j <br /> pressure/vacuum/water and <br /> startinR test <br /> Test Start Time: 8:06 am 8:06 am <br /> Initial Readin ,): 1 3859" 2.4150•, <br /> Test End.Time: 8:21 am 8:21 am <br /> Final Reading 1.3910" 2.4149" <br /> Test Duration.: 15 minutes 15 minutes <br /> Chane in Reading(RF-R[): .0021"Increase .0001"Loss <br /> Pass/Fail Threshold or Criteria: Loss<_002"=pass iross<.002 ass <br /> Test Result: X Pass 0 Fail X Pass ❑Fail 0 Pass ❑Feil ❑ Paso p Fail <br /> Was sensor removed for testing? XYes ❑No ❑NA XYes ❑No i❑NA ❑Yes 11 No ❑NA 0 Yes 0 No 0 NA <br /> Was sensor properly replaced and XYes ❑No ❑NA XYes ❑No ❑NA ❑Yes ❑Na El NA 71 Yes :1 No 11 NA <br /> verified functional after testln ? <br /> Comments—(include itrformation on repairs made prior to resting, and recommended follow y for failed tests) _ <br /> ten _allntry boot claln�s and shl down gas disy�l�sing for t _ <br /> duration <br /> ' Ifthe entire depth of the UDC is not tested,specify how much was tested. Ifthe answer to�My ofthe questions indicated with an <br /> asterisk(')is"NO"or"NA",the entire UDC must be tested. (See S WRCB TG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.