My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2004-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
1427
>
2300 - Underground Storage Tank Program
>
PR0521942
>
COMPLIANCE INFO 2004-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 9:18:31 AM
Creation date
11/2/2018 8:12:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2007
RECORD_ID
PR0521942
PE
2371
FACILITY_ID
FA0014921
FACILITY_NAME
RANCHO SAN MIGUEL MARKET*
STREET_NUMBER
1427
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
16902016
CURRENT_STATUS
01
SITE_LOCATION
1427 S AIRPORT WAY
P_LOCATION
02
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\A\AIRPORT\1427\PR0521942\COMPLIANCE INFO 2004-2007.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 ? ga e 6 of 7 <br /> S. ,FILL RISER CONTAXNWNT S1tJW TESTING <br /> --Facility is Not With Fill Riser Containment Sums 0 <br /> Fill Riser Containment Sum s are PmeM but were Not Tested i_i <br /> Test Method Developed.By: Q Sump Manufacturer X Industry Standard 11 Professional Engineer <br /> ❑Other(Specify) <br /> Test Method.Used: ❑Pressure 1?Vacuum X Hydrostatic <br /> ❑Other EEC*) <br /> Test Equipment Used:Incon TS STS Equipment Resolution: <br /> dill Sam 987 Fill Sininp 491 >p'ila SUME it Fill Sam 4 <br /> Sump Diameter: 42" 42" <br /> S D 48" 4V' <br /> Height from Tank Top to Top of i 2" 12" <br /> Hi est Pi in Penetration: <br /> Height from Ta k Top to Lowest t$" 18 <br /> .Electrical Penetratiam <br /> Condition of sump p;for to Clow Clean <br /> testi <br /> Portion of Sump Tested Full Full <br /> -Sump Material: Fiberglass Fa lass <br /> Wait time between applying 10 minutes 10 Minutes <br /> pressurelvacuum/water and <br /> statin test.- <br /> Test <br /> est:Test Start.Time: 3:40 pm 3:40 22 <br /> Initial Readin 2.6319" 5.5094" <br /> Test End Time: 3:55 E2 3:55 Pm <br /> Final Reamg(RI,); 2.6320" 5.5043" <br /> Test Duration: 15 Minutes 15 Minutes <br /> Chmge in Reading r-Ri): .0001" -.0001 <br /> Pass/Fail Threshold or Criteria: .002 <.p02": ass <br /> Test Reatftt X Pass 0 Fail X lass ❑FAil C! Pass C Fail 7 Pass 7 Fail <br /> 1s there a sensor in the surap? X Yes ❑No X Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> Does the sensor alarm when <br /> either product orr water is XYes O No ❑NA XYes ❑No [INA ❑Yes ❑No L NA 7 Y z ❑Flo P NA <br /> detected? <br /> Was sensor removed for testin R? XY% ❑No ❑NA XYes ❑No i"NA ❑Yes ❑No O NA Q Ym ❑No ❑NA <br /> as sensor properly replaced and <br /> verified fimctianai atter tes' ? XYes ❑l�To ❑NA XYes O No ❑NA ❑Y (])tio C3l`1A ❑Ys ❑I�lo -7 NA <br /> Comments—(include infOrTGOOn an re irs made Efor xa Legi t and recommended l 2ny ar ailed tens <br />