COMPLIANCE INFO 2004-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
1427
>
2300 - Underground Storage Tank Program
>
PR0521942
>
COMPLIANCE INFO 2004-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 9:18:31 AM
Creation date
11/2/2018 8:12:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2007
RECORD_ID
PR0521942
PE
2371
FACILITY_ID
FA0014921
FACILITY_NAME
RANCHO SAN MIGUEL MARKET*
STREET_NUMBER
1427
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
16902016
CURRENT_STATUS
01
SITE_LOCATION
1427 S AIRPORT WAY
P_LOCATION
02
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\A\AIRPORT\1427\PR0521942\COMPLIANCE INFO 2004-2007.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 ?age 5 of 7 <br /> 7. UNDER-DISPENSER CONTArOMNT TESTING <br /> Test Method Develaped By: ❑UDC Manufacturer X Industry Standard ❑Professional Engineer <br /> ❑Other(Sped) <br /> Test Method Used: ❑Pressure 0 Vacuum X Hydrostatic <br /> ❑Other(33peaify) <br /> tTecqdquipment Used:Incem TS STS Equipment Resolution: <br /> UDC#1-2 LW#1;3-4 UDC#&6 UD( # <br /> Manufacturer: Environ Environ Environ <br /> Material: Po pot Pot Depth 33" 33" 33" <br /> Height from UUC Bottom to Top 4" 4" 4- <br /> of Hi est Piping Penetration: <br /> Height from UDC Bottom to 15" 15" 15" <br /> Lowest Electrical Perieft-ation: j <br /> Condition of U1DC prior to Clean Clean Cleantesting: <br /> Portion of UDC°T'ested Full Full Full <br /> Does turbine shut down when <br /> UDC sensor detects liquid('both XYes ❑No ❑NA XYes D No ❑NA XYes ❑No ❑NA ❑Y2s ❑No DNA <br /> product and water)?. <br /> Twbine shutdown re »se time 2 Seconds 2 Seconds 2 Seconds <br /> Is system programmed for fail- XYes ❑No ❑NA XYcs 0 No ❑NA XYes ❑Na ❑NA ❑Y-m ❑No ❑NA <br /> safe shutdown?" <br /> Was fail-safe vcri fi ed to be XYes ❑No ❑NA XYes, ❑No ❑NA XYes ❑No ❑NA ❑Y as ❑No ❑NA <br /> overational?, <br /> Wait time between applying 10 Minutes 10 Minutes 10 Minutes <br /> pressurelvacuum/water and <br /> starting test <br /> Test Start Time: 4:51pm 4:51 pm 4:51 eT <br /> Initial Readiu 6.6009" 2.1843" 3.8229" <br /> Test End Time: 5:06 2T 5.06 pm 5:06 pm <br /> Final Reading_ F): 6.6008" 1.$572" 3.4917" <br /> Test Duration: 15 Minutes 15 Minutes 15 Minutes <br /> Chan a in Readm r N: -.0001" -.3271" -.3312" <br /> Pa&-vTail Threshold or Criteria: ¢.002"= ass 002"=pass <002" <br /> Test Result: X Pass ❑rail ❑ Pass X Fail ❑ Pass X Fall M Pass ❑Fail <br /> Was sensor removed for testing? XYes ❑No ❑NA XYes ❑i No ❑NA XYes ❑No ❑NA ❑Yi s 0 No 0 NA <br /> Was sensor properly replaced and XYes ❑No ❑NA XYes 0 No ❑NA XYes ❑No i'NA ❑Ys s ❑No :D NA <br /> verified functional after testin ? <br /> COMMeDts—L�rclude tnformatfon on repairs made prior to testing and recymmendedfMk'►v�for failed te� <br /> ..-Thee entries wee all tightened- u� ed t_ <br /> If the entire depth of the UDC is not tested,spccwy bow much was tested. if the answer to M of the questions indicated with an <br /> asterisk M is-N("or"NA",the eatin UDC must be tested. (See SWRCB LG-160) <br />