My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
4800
>
2300 - Underground Storage Tank Program
>
PR0231509
>
COMPLIANCE INFO 2008 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2024 4:04:57 PM
Creation date
11/2/2018 8:31:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2015
RECORD_ID
PR0231509
PE
2361
FACILITY_ID
FA0003809
FACILITY_NAME
A G SPANOS AVIATION DEPT*
STREET_NUMBER
4800
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
01
SITE_LOCATION
4800 S AIRPORT WAY
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\A\AIRPORT\4800\PR0231509\COMPLIANCE INFO 2008 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2008 - 2015
QuestysRecordDate
9/14/2017 6:56:06 PM
QuestysRecordID
3636962
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
265
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWKCB, January 2002 <br /> Page of <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑Sum Manufacturer <br /> Q Industry Standard Professional Engineer <br /> El Other(Spec) r . <br /> Test Method Used; _ _Q Pressure _ <br /> ._. C]Vacuum.. <br /> Test Equipment Used: ''�+L, f L <br /> ❑Other(Specify) <br /> -e, r.. .,, <br /> Equipment Resolution; t,-.� <br /> qz <br /> - Sum # L <br /> Sump Diameter: p Sump# .- Sump# 3 Sump# <br /> Sump Depth: Lt, <br /> Sump Material. Lk)_11 <br /> Height from Tank Top to Top of <br /> Hi est Pi ing Penetration: 2t,r` 3 (ol1 g rl <br /> Height from Tank Top to Lowest - f} <br /> Electrical Penetration: 2.q f! 3 6' e <br /> u <br /> Condition of sump prior to testing: r 1.1Z3 <br /> � �� <br /> Portion of Sump Tested' „ F) M�r <br /> Does turbine shut down when j"'PC p e AAL 2-'s <br /> sump sensor detects liquid(both <br /> Product and water)? Oes 11No 0 NA IJNo LlNA 11es ❑No ❑NA lyes No ❑NA <br /> Turbine shutdown response time N� c 4ce;1 <br /> Is system programmed for fail-safe " <br /> shutdown?* ?,`Yes ❑No ❑NA )'Ies ❑No ❑NA Yes ❑No ❑NA es Q No ❑NA <br /> Was fail-safe verified to be <br /> operational?* ❑ Yes �Mo ❑NA ❑Yes Kio Q NA ❑Yes ;ZNo ❑NA D Yes' 'No ❑NA <br /> Wait time between 1uig <br /> pressure/vacuum/ester d starting <br /> test: r <br /> Test Start Time; <br /> : <br /> Initial Reading(Rr): I1.'Sv /� 3c)r�,1s� <br /> Test End Time: ��.'y 5� <br /> Final Reading ` <br /> �s t{:e <br /> Test Duration: <br /> Change in Reading(RF-R,): I <br /> U/_ it ctt r-YS , />.•:� r•J r <br /> D >^ U,✓) r- f t+-•.-� 'L atICJ�� t�..�` l^ ..l/'� �,�°(' <br /> t � <br /> Pass/F`ail Threshold or Criteria: ��,� - cf f� r <br /> c.) g 3 /,-(,r / . oe)� <br /> Test Results `fd°Pass ❑Fail Pass ❑Fails,Rr Pass Q Fail Pass d Fall <br /> Was sensor properly replacedacedand <br /> Was sensor removed fartesting? es Q No ❑NA es Q No Q NA �,Yes ❑No ❑NA ,0'es 12 No ❑NA <br /> d <br /> verified functional after testis ? es 11 No ❑NA Aes ❑No ❑NA Yes ❑No ❑NA KYes ❑No ❑NA <br /> COIIIMepts - (include information on re airs made prior to testis , and recommended ollow-u nr failed tests) <br /> If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*) is "NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.