My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
4800
>
2300 - Underground Storage Tank Program
>
PR0231509
>
COMPLIANCE INFO 2008 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2024 4:04:57 PM
Creation date
11/2/2018 8:31:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2015
RECORD_ID
PR0231509
PE
2361
FACILITY_ID
FA0003809
FACILITY_NAME
A G SPANOS AVIATION DEPT*
STREET_NUMBER
4800
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
01
SITE_LOCATION
4800 S AIRPORT WAY
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\A\AIRPORT\4800\PR0231509\COMPLIANCE INFO 2008 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2008 - 2015
QuestysRecordDate
9/14/2017 6:56:06 PM
QuestysRecordID
3636962
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
265
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I� s <br /> ),r <br /> MONITORING SYSTEM CERTIFICATION S <br /> For Use By All Jurisdictions Within the State of California !' <br /> Authority Cited: Chapter 6.7, Health and Safety Code;Chapter 16, Division 3, Title 23, California%C,q�+,f` ? i <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification for each <br /> monitoring system control 12anel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General information <br /> Facility Name: A.G. S anon Aviation Bldg.No.: <br /> Site Address: _4800 S Airport Way City. Stockton Zip: 95206 <br /> Facility Contact Person: Thomas Contact Phone No.: (209) 982-1550 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 212112008 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate s ecine a ui anent inspected/serviced: <br /> Tank ID: T1: Jet Fuel West Tank ID: T2:Jet Fuel East <br /> 0 In-Tank Gauging Probe. Model: 8473-90-109 ®ln-Tank Gauging Probe. Model: 8473-90-110 <br /> •Annular Space or Vault Sensor. Model: 794390-420 ®Annular Space or Vault Sensor, Model: 794390-409 <br /> •Piping Sump/Trench Sensor(s). Model: 794380-208 0 Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill I High-Level Sensor. Model: <br /> ®Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: T3 :Jet Fuel East 2 Tank ID: <br /> ®In-Tank Gauging be. Model: 8473-90-107 ❑In-Tank Gauging Probe. Model: <br /> ®Annular Space or Vault Sensor. Model: 794390-409 ❑Annular Space or Vault Sensor. Model: <br /> ®Piping Sump 1 Trench Sensor(s). Model: 794380-208 ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill 1 High-Level Sensor. Model: ❑Tank Overfill I High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Floats)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sertsor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser iD: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). I ❑Dispenser Containment Float(s)and Chain(s). <br /> If the facility contains more tanks or dispensers,copy this form. include information for every tank and dispenser at the facility. <br /> C. Certification -1 certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also <br /> attached a copy of the report;(check all that apply): System set-up ®Alarm history report <br /> C <br /> Technician Name(print): Guadalupe Sanchez _ Signature• �- <br /> Certification No.: A30138 License.No.: 883706 <br /> Testing Company Name: Reliable Petroleum Services Inc. Phone No.: (209) 845-8586 <br /> Site Address: 521 Branding Iron St. Oakdale Ca.95361 Date of Testing/Servicing: 2/21/2008 <br /> Page 1 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.