My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
7611
>
2300 - Underground Storage Tank Program
>
PR0231511
>
COMPLIANCE INFO 2013 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2022 3:30:17 PM
Creation date
11/2/2018 9:09:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2016
RECORD_ID
PR0231511
PE
2361
FACILITY_ID
FA0003695
FACILITY_NAME
ESTES TRUCKING
STREET_NUMBER
7611
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
17705029
CURRENT_STATUS
01
SITE_LOCATION
7611 S AIRPORT WAY
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\A\AIRPORT\7611\PR0231511\COMPLIANCE INFO 2013 - 2016.PDF
QuestysFileName
COMPLIANCE INFO 2013 - 2016
QuestysRecordDate
1/23/2018 6:18:21 PM
QuestysRecordID
3769490
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
223
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 RECEIVED <br />S. FILL RISER CONTAINMENT SUMP TESTING D�f96"1 <br />Facility is Not Equipped With Fill Riser Containment Sumps X <br />Fill Riser Containment Sumps are Present, but were Not Tested i <br />Test Method Developed By: C] Sump Manufacturer DEPARTMENT <br />Industry Standard ❑ Professional Engineer <br />—0 Other (Sped) <br />Test Method Used: ❑ Pressure <br />[J Vacuum 11 Hydrostatic <br />❑ Other (Sped) <br />Test Equipment Used: <br />_ } Filly Sump # <br />S1111]p Dian1c'ter: <br />Sum De the <br />Height from Tank Top to Top of <br />Hi hest Pi in Penetration: <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />Condition of sump prior to <br />testin : <br />Portion of Sura Tested <br />Sum Material: <br />Wait time between applying <br />water and startin test: <br />Test Start Time.- <br />Initial <br />ime:Initial Readin <br />Test End Time: <br />Final Readin (RF): <br />Test Duration: <br />Change in Reading (RF-Rr): <br />Pass/Fail Threshold or Criteria: <br />Test Result: <br />is there a sensor in the sump? <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />Was sensor removed for testin ? <br />Was sensor properly replaced and <br />verified functional after testinO <br />Equipment Resolution: <br />Fill Sump # ["if] Sum # <br />l Fell Sun] ;z <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />