Laserfiche WebLink
SAN JOAQUIN COUNTY RECEIVED <br /> ENVIRONMENTAL HEALTH DEPARTMENT JUN 2 <br /> 600 East Main Street, Stockton, California 95202-3029 Q 2011 <br /> Telephone:(209)468-3420 Far:(209)468-3433 Web:www.sigov.org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTIONMENTAL HEALTH <br /> IT/SERVFCES <br /> Facility name: Inspection date: <br /> Estes Trucking May 27, 2011 <br /> Factory,address: UST IF1 2 <br /> 7611 S Airport Way, Stockton CA Prodaa DSL ' <br /> Facility cordack Title: Phone: , <br /> Travis Horton Terminal Manager 982-1841 ' <br /> Monitoring panel: Piping system: Overfill prevention: Violations: <br /> Veeder-Root TLS-350 ❑XPressudzed�uchon❑Gravlty ®Mudible s [:]Ml-RDeled❑M2-RPrev❑M38oth <br /> ❑meh Msual <br /> Inspection type: Designated operator: ICC exp.data: <br /> ®Routine 0Monitoring Certifiration E]Installation ❑Omer Ryan Bunck 10/15/12 <br /> On sero Servke Technician's name: ICC exp.dots: Manufacturees training: <br /> Felix Ramirez b d (yie-&P46�1497tii, (-1 12., \W II (I <br /> VIOLATIONS R <br /> t Code Section HSC=CA Health&safety Code;CCR--CA Code of Regulations;V=Violatiorc RV--Repeat Violation V V <br /> 1 HSC 25284 No peit to operate <br /> Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(f)test <br /> 2 CCR 2637 notification not provided to the Environmental Health Department(EHD)at least 48 hours prior to X <br /> conducting the test <br /> 3 CCR 2711 b Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank forth X <br /> 4 HSC 25292.2 Current financial responsibility documents not on file with the EHD X <br /> 5 CCR 2632(b) Monitoring Program(Monitoring&Response Plans is not current or approved by the EHD X <br /> 6 CCR 2712(i) Monitoring Ian,response plan,and/or operatini permit and all conditions not onsite X <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6'.4 (r+) <br /> years,written performance claims pertaining to release detection systems for 5 years,or records of <br /> repairs,linings,and upgrades for the life of the tank. Monitoring records include:(1)date and time of <br /> 7 CCR 2712(b) all monitoring or sampling; (2)monitoring equipment calibration and maintenance records;(3)results <br /> of any visual observations;(4)results of sample analysis performed a lab or in the field;(5)logs of all <br /> readings of gauges or other monitoring equipment,ground water elevations,or other lest results;(6) <br /> results of inventory readings and reconciliations <br /> 8 1 CCR 2643(d) Daily monitoring of suction anus 1 1984 not performed rt _ <br /> 9 1 HSC 25292.1 UST system is not operated to prevent unauthorized release,including spills and overfills <br /> 10 CCR 2632 c 2 Monitoring system is not present in the interstitial space of a double walled LIST Poll <br /> 11 CCR 2630(d) UST monitoring u' ment is not installed or maintained to detect a leak at the earliest o unit <br /> 12 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary (M1) <br /> containment <br /> 13 CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping&UDCs that activates (n) <br /> an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 14 CCR 2631 a Primary containment is not product tight <br /> 15 HSC 25291 a 2 Secondary containment for UST system is not tight <br /> 16 CCR 28 c 1 All releases in secondary pipingdo not flow to a collection sum <br /> 17 CCR 2636(f)(2) Line leak detector(s) not installed or failed to detect a ailon per hour leak at 10 psi full <br /> 18 CCR 2635(b)(1) Spill container failed to contain a minimum capacity of five gallons,or failed to provide a means (ax) <br /> to keep the spill container empty <br /> 19 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements in this section <br /> 20 CCR 2636(a) Failed to have secondary containment for piping(includes conventional suctionpiping) <br /> 21 HSC 25291 a Water in 2'containment not removed,analyzed&properly disposed of <br /> Unauthorized release that:(c)rid not escape secondary containment and cleaned up within eight (M+) <br /> 22 CCR 2650 hours was not recorded;(e)escaped secondary containment, not cleaned up after eight hours,or a <br /> sudden loss of product was not reported to the EHD within 24 hours <br /> 239 CCR 2715 a Failed to inform the EHD of a change of designated operator within 30 days <br /> 23b I CCR 2715(b) Designated operator did not possess a current ICC UST System Operator certification <br /> EHD i Received by: Title: <br /> EHD -002 0&13110 Page l UST INSPECTION REPORT <br />