Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton,California 95202-3029 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.rigov.orq/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility address: Inspectlon Date: <br /> 7611 S Airport Way, Stockton CA May 27, 2011 <br /> 0Code Section VIOLATIONS V R <br /> HSC=CA Health&Safety Code;CCR=CA Code of Regulations;V=Violation RV=Repeat Violation V <br /> Designated operator monthly inspection:(c)(1)alarms not documented:(c)(2.4)spill containers, <br /> 23c CCR 2715(c), (e) UDCS,and sumps(if necessary)not inspected;(c)(5)required test dates not checked or noted;(c)(6) X <br /> employee training not verified;(e)monthly inspection reports not maintained on site for at least 12 <br /> months <br /> 23d CCR 2715(f) Designated operator employee training: (1)not performed;(2)not current for at least one employee X <br /> on site 3 not kept <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 <br /> 24 CCR 2638 days;(e)test notification not provided to the EHD at least 48 hours prior to conducting an installation, <br /> repair, replacement,calibration,or certification;(f)performed,and failed to affix a tagisticker on each <br /> monitoring equipment component that was certified repaired,or replaced <br /> 25 HSC 25291 Annual line leak detector test not performed (M1) <br /> 26 HSC 25284.2 Annual spill containment testing not performed <br /> 27CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe rat present Nil <br /> 28 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to permit IM21 <br /> conditions <br /> 29 CCR 2643(e) Biennial tightness test of gravity pipingnot performed anus 1 1984 <br /> 30 CCR 264 d Triennial line test for Conventional suction piping not rfomred anus 1 1984 <br /> 31 HSC 25292.5 ELD testing not performed on a system located within 1000'of public well,or failures not repaired and <br /> retested <br /> 32 CCR 2661 Pemrit to repair UST System not obtained <br /> 33 HSC 25286(a) rational permit not amended when UST stone and/or monitoring system charmed <br /> 34 HSC 25298(b) Permit to temporarily dose UST system not obtained <br /> 35 HSC 25298(c) Permit to dose UST system not obtained <br /> 36 HSC 25299(f)(2) Tampering with or disabling leak detection devices or alarms <br /> 37 HSC 25298(a) Illegally abandoned UST system <br /> 38 HSC 25281.5 b 2 Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br /> 39 CCR 2631.1 a UST system is not compatible with the substance stored <br /> Emergency generator systems <br /> 40 1 CCR 2636(f)(6) E enerator monitoringsystem not checked dail or I not t if no leak detector <br /> 41 HSC 25281.5 b 3 Uencnburied fuel i Ing not visually inspected at least monthly or log not kept t <br /> AB 1702(2003.2004) HSC 26290.2(installed between 07/01/03 and 09/301(14) <br /> VPH Systems HSC 26290.1 Installed on or after 07/01/04 <br /> Compatibility and permeability requirements:(a)UST system is not compatible with the substance <br /> 42 CCR 2631.1 stored;(b)results of the Compatibility and permeability testing requirements listed in subsections CCR <br /> 2631(b)and d fora UST system installed after July 1 2004,were not submitted <br /> 43 HSC252 '(c)(1) <br /> HSC 25290.2c 1 primary containment not liquid or vapor tight <br /> 44 HSC 25290.1(c2 c)(2) <br /> HSC 25290.2 Secondary containment not liquid or vapor tight <br /> 45 HSC 25290.1(C)(3) Secondary containment not constructed to prevent water intrusion <br /> HSC 25290.2 c 3 <br /> 46 HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary Containment,or pat) <br /> HSC 25290.2(d) the entry ofliquid or vapor from the primary containment into the secondary containment <br /> 47 HSC 25290.1(e) Interstitial liquid measurement method,constant vacuum,or constant pressure in the interstitial (aa) <br /> ace of the UST system not maintained <br /> HSC 25290.1() UST system not tested by one of the following methods prior to use:(1)Enhanced leak detection;(2) <br /> 48 HSC 25290.2(1) inert gas pressure test approved by SWRCB;(3)test method deemed equivalent to(1)or(2)by the <br /> SWRCS <br /> Other violations <br /> 999 1 Other: I See nanuadon—Official Inspection Reporr for violations not listed above. _ <br /> EHD inspatar: Phoma: UIC <br /> Septicsystem. <br /> / 1537v ',Serves <br /> >20 people/day <br /> Reeaved by: Title: '.;Receives otter than sanitary waste <br /> Other disposal methods: <br /> Dry wells/French Drains <br /> EHD 23-02-002 REV 0&13/10 Page 2 UST INSPECTION REPORT <br />