Laserfiche WebLink
SWRCB.January 2002 Page 4 of 7 <br /> Site: Estes Trucking <br /> 7611 S. Airport Way <br /> Stockton,CA 95205 <br /> Date: 09/22/2010 <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: [ ] Sump Manufacturer [X] Industry Standard [ ] Professional <br /> Engineer <br /> [ ] Other(Spec) <br /> Test Method Used: . ( ] Pressure [ J Vacuum IX ] Hydrostatic <br /> Other'Scecif}) _ <br /> Test Equipment Used: CALDWELL LEVEL GAUGE Equipment Resolution: 0.0025 <br /> Sump#1 <br /> Sump Diameter: __ 48 Inch <br /> Sump Depth: 36 Inch <br /> Sump Material: Fiberglass <br /> Height from Tank Top to Top of 30 Inch <br /> Hi hest Pi in Penetration: <br /> Height from Tank Top to Lowest 20 Inch ------- ------- ------.--- — _- <br /> Electrical Penetration: <br /> Condition of sump prig to testin <br /> - - -------- <br /> Portion ofmfested —_— 32 in <br /> Does turbine shut down when sump XIYES__ I NO _ . YES( <br /> I NO <br /> sensor detects Iquid(both product& [ INA I I NA ( INA [ INA <br /> water)? <br /> Turbine shutdown response time: -- ------ —^--------- �— ----- —. <br /> Is system programmed for fail-safe [.XI YES [ I NO [I YES[ ]NO [I YES[ I NO [ I YES( I NO <br /> shutdown? __ [ INA (INA I INA I INA <br /> I Was fail-safe verified to be (XI YES[ I NO ( ]YES[ ]NO []YES[ ]NO [ J YES[ ]NO <br /> operational? [ INA I INA I JNA [ INA <br /> Wait time between applying <br /> pressureivacuum/water and starting 5 Minutes <br /> test: <br /> Test Stan Time: 10:55 A.M. <br /> Initial Reading(R I): _ 32lnch --- -- ----- — --------- — <br /> Test End Time: ___ 11 S5 A.M. <br /> Fina( Reading(Rf): 32 Inch <br /> Test Duration: 1 Hour _ <br /> Change in Reading R( f-RI) -0- <br /> h PassiFail Threshold or Criteria:__ _-0- _ _ <br /> Test Result: _ IXI PASS [ I FAIL ( I P:\SS_[ I F:\lI. [ 1 PASS [ I F AIL I I PASS I I NO - - <br /> -__ —. <br /> Ras sensor removed [itr testing? IXI YES ----[ I NO 7[�YFS ( I NO � I I YES ( I NO ( I 7"I:S I I NO <br /> �.-- ---- N=\— ------�w. -------LL-LNL --- — .1 1 N`\----- -- <br /> Was sensor properly rep:aced and IXI YES [ 1 NO I I N'I`.S I-:U i t 1 YES I I NO I I YES I I <br /> verilied functional eller testin ' [ I N A I I N-�\ [ I N'\ I I N.\ <br /> — Famments (include-informarro"rf-repairs-math prioT t -restingand recamnrenzdL-d-faltaw=up fortaited tests) <br /> I If the entire depth of the sump is not tested.specify ho" much w;n tested. If the answer to any of the questions indicated with an asterisk(')is :NO""or <br /> -NA'.the entire sump must be tested (SW 1X'13 LG-160) <br />