Laserfiche WebLink
ENVIRONMENTAL HEALTH DEPARTMENT <br /> SAN JOAQUIN COUNTY <br /> Donna X. Seraa, Una Supervisors <br /> e . R.Z.H.S. 304 East Weber Avenue' a <br /> Third Floor Carl Borgmn, R.E.H.S. <br /> Director Mike Huggins, R.E.H.S., <br /> Al Olsen, R.s.R.S. Stockton, California 95202 R.D.I. <br /> Program Manager Douglas W. Wilson, <br /> Telephone: (209)468-3420 <br /> Laurie A. Cotulla, R.E.H.S. <br /> R.B.B.S. ( ) ar Fax: 209 464-0138 Morio, <br /> Margaret La <br /> - .- <br /> R.E.H.S. <br /> Robert McClellon, <br /> APPLICATION FOR PERMIT TO CLOSE R.E.H.S. <br /> UNDERGROUND STORAGE TANKS STORING HAZARDOUS MATERIALS <br /> I. GENERAL INSTRUCTIONS: <br /> [] <br /> I. Submit all information in triplicate. Answer all questions, leaving no blanks. One copy will be returned to <br /> the applicant with comments. <br /> [] 2. Include a detailed site map on a separate sheet of paper,showing the location of the tanks(s),piping,streets, <br /> adjacent properties (north toward the top of the page), nearby septic tanks, leachfields, water wells, <br /> buildings,underground public utility lines(including water,sanitary sewer and storm sewer), and distance <br /> of piping from tank to dispensers. If underground utilities are not included on the site map,you must state <br /> in writing that USA Dig will be contacted prior to excavation activities. <br /> [ � 3. Complete page 3, "Application for Underground Storage Tank Closure Permit". o[ . Sampling firm <br /> shall be an indeoendent third party from the contractor. <br /> [] 4. Complete page 9, "Authorization to Release". This form must be signed and dated by the <br /> OWNER/OPERATOR of the facility. <br /> [] 5. Submit a"Service Request"form with the appropriate fees, submit completed UPC forms for Facility and <br /> Tanks (formerly State A & B forms) and complete page 11, the "Underground Storage Tank Program <br /> Fee Worksheet'. <br /> [] 6. Complete all questions on page 10,the Environmental Health Department(EHD) "Underground Storage <br /> Tank Disposition Tracking Record" except those requiring a signature and date of tank removal. The <br /> holder of the permit shall be responsible for ensuring that this form is completed and returned to EHD <br /> within 30 days of the tank removal. <br /> [] 7. Submit a"Site Health& Safety Plan"as an addendum to this application,to address all potential hazards <br /> for this specific job site. Refer to the Site Safety Plan Guidance Document for specifics. <br /> [] 8. If facility is located outside of the city limits,submit a "Backfill Excavation Certificate" as required by <br /> the County of San Joaquin Building Department and the incorporated City Building Departments,pursuant <br /> to the Uniform Building Code STD 70-11. <br /> [] 9. Obtain a "Grading and Excavation Permit" from the City of Tracy Building Division prior to EHD <br /> approval of the closure plan. <br /> [] <br /> 10. The maximum review time for Closure Plans is 15 working days from receipt of the adequately completed <br /> plan. If gross deficiencies are identified, an addendum will be required with a S93.00/hour fee and the <br /> review will begin on the date of resubmittal. <br /> [] 11. Submit verification of the fire permit from the appropriate fire district at the removal inspection. <br /> [] 12. Advance inspection notice of at least 48 hours is required by EHD <br /> (] 13. Submit Contingency Plan for over-excavation at time of UST removal(if planning to over-excavate). <br /> See"III. SITE MITIGATION"on Page 2. <br /> EH 23 046 (Revised 10/16/03) Pagel <br />