4627
>
2300 - Underground Storage Tank Program
>
PR0231074
>
REMOVAL_1998 PLAN
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:43:34 PM
Creation date
11/4/2018 2:20:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
1998 PLAN
RECORD_ID
PR0231074
PE
2361
FACILITY_ID
FA0002541
FACILITY_NAME
7-ELEVEN INC #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11002003
CURRENT_STATUS
01
SITE_LOCATION
4627 DA VINCI DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DA VINCI\4627\PR0231074\REMOVAL PLAN 1998.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'RETAIL AUTf)MAT;ON GCMPl7TER NOTES SURFACE MOUNTED CABLE DUPLE% RECEPTACLE 12 4 PLEX LAN CABLES --��� "" _ "--_ __-_�"• # �y <br /> 14 4 LAN CABLESu,. a . - *•e"` <br /> ., <br /> ON BACK ROOM WALLS TO BATTERY (1) PER REGISTER PLUS FUTURE k ( r (10 <br /> 1 Workstation Table <br /> GTM 2 PLEX FOR CABLES 16 TELEPHONE 2 LINES <br /> p (CPU) 2 (1) FOR M.O. BATMAN CABLE N2 DEDICATED COMPUTER MODEM LINE <br /> 2, Retail Automation Computer CPU 15 <br /> 3. Monitor (1) FUTURE (ft TELEPHONE VOICE LINE 0 <br /> GAS . e �eL_ FROM TELEPHONE BOARD <br /> 4, Keyboard CONTROLLER <br /> 5. Printer (]p <br /> 5. Buttery a <br /> 7. Router .RADE <br /> r <br /> 8. Hub <br /> 9. Modem <br /> 10. Handheld Cradle <br /> 11. Optional fan and task light (served by auxiliary duplex outlet) MODEM 7 - <br /> 1'2. New duplex receptacle which receives the following plugs; 5 13 BA KR OM <br /> (1) Battery; (2) Future; �7.� , <br /> 4 y <br /> 13. Computer battery receptacle will receive the following plugs. Sea Retail <br /> Automaton Workstation elevation this sheet. �P 1 <br /> (1) CPU; (2) Cradle; (3) Monitor; (4) Power Strip (Supplied by NCR installer) r7r 1 <br /> a f- <br /> 14. The computer will receive four (4) 100 foot category 5 Sysdimox LAN cables (3 for registers; `',-/ 0_ 4 <br /> one future) run from sales area registers through a one inch concuit (see I OFFICE <br /> SALES' <br /> Wiring Diagram this sheet) and terminate at a four outlet cable jack with a 4 FIN. FLR. TRANSFORMER PLUGS - AREA ' I <br /> outlet faceplate which meets category 5 transmission requirements as <br /> exemplified by Model MPS100BH type with corresponding face plate. i_T I fl <br /> Register LAN cables will sub up out of the floor at each register location. See 26 SIX PLEX STRIP (BY NCR) ,,,,,R„„";;"" <br /> Sheet E-1. _ 18" 18" IR-^-711 <br /> - tIG,X_y11-_ <br /> J6" i <br /> -'-- - <br /> 15. The computer will receive the following additional data cables. - ,(•• -^�•�1,C�t� <br /> (1) Cheyenne Money Order Cable-- Batman cable; (2) Future lottery, safe cables. .. d <br /> Data conduit will have R5232 and D825 connectors. There are two (2) 1/0 o <br /> cables from the computer 25 DBA connectors for money order machine. N E YY STORE RETAIL AUTOMATION <br /> - - <br /> Cables will run form the ISP workstation through a one (1) inch conduit ,[, 7/r \JRKnJTATION ELEVATION LIJ <br /> �T <br /> termination at the sales area backwull (see Wiring Diagram this sheet). fi1'4 N07 TO SCALE <br /> 20 AMP CIRGUR /'"l 19 C? <br /> 18. Telephone lines: Telephone wiring from telephone panel to dual RJ11 FOR ISP COMPUTER �/ I im <br /> receptacle by telephone subcontractor. Location for receptacle is marked by 4 PEE% <br /> electrical subcontractor. Line p1 is telephone voice line from telephone board. <br /> //'�+ ('� / � <br /> Line jig is a dedicated computer modem line. 20 AMP CIRCUIT 1 _ ELECTRONIC EQUIPMENT -r <br /> Final interface connection to DMARC board is by telephone contractor. FOR POS I �K <br /> Telephone contractor will label the DMARC with appropriate LEC and IXC REGISTER 20 / , - <br /> RECEPTACLES // E ECSHEET PANEL 3 P.A R T PLAN <br /> circuit carriers. Label line 1 and line 2 at the ISP. / 24 S E SHEET E-IA <br /> 17, Auxiliary duplex receptacle for fan and light only. EP4 ALEt/8+a`�i+_Q+ <br /> 18. One inch PVC in wall for data cables. See notes 14 and 15 above and wiringTELEPHONE WIRING a m p 444t <br /> diagram on this sheet. 1 F) // +, cc) r 1- <br /> 19. Cheyenne Money Order Machine. See note 15 above and Wiring Diagram / chi) Q4'r 0 <br /> this sheet. <br /> 2D. Point of Sale (POS) register. ___-._--.-_-17.;1 TELEPHONE PANEL �y7 it 5(P <br /> 21. Floor mounted 4 plex receptacle with one receptacle accessible ( others <br /> covered with outlet caps similar or equal to Leviton No.12777.) Receptacle \ <br /> will be similar or equal to Raco Model No. 192 four (4) square outlet box c4 <br /> Modelwith a quad cover similar to Roco Model No. 807 with two (2) Hubell - i N n <br /> Model No. 5252 duplex receptacles, GIM DATA CABLE <br /> UITS 22 `•� <br /> Receptacles required CO <br /> red at each POS register location. Receptacles are part of I <br /> a 20 AMP IDG circuit with separate sub-ups at each register. See Wiring 10 11 12 13 14 15 18 <br /> Diagram this sheet and sheets E-1 and E-IA of the construction documents. <br /> SEE DETAIL ABOVE .I <br /> 22. Gasoline Tank Monitor cable and future cables for Gas Controller/CRINO y -? r) G rK <br /> Cables run form device to backroom computer with cables fastened \ '. a, <br /> to wall. (Conduit not required). <br /> 23. Telephone panel (see sheet E-1 for location). Local telephone company makes all 8 w ' <br /> telephone connections. Orders for new telephone lines are, coorinated by the local market. <br /> if local market needs assistance, call 214 -828-7942. I .l / Lce r- <br /> h d V <br /> 24. Electrical panels. See Sheat E-1 of the construction documents. <br /> � 60 7 <br /> 25. ATM electrical and telephone line by ATM vendor. 15P EIACKROOM <br /> 25 COMPUTER SALES COUNTER .. <br /> 26. New 6 Alex power strip supplied by NCR installer. �� <br /> �\ CINTf <br /> ATM RJa5 CONNECTOR <br /> G Rd45 CONNECTOR <br /> GAS CONTROLLER CABLE HOOD �l 5 _ CON <br /> 002,5 FEMALE CONNECTOR AT <br /> ISP END AND HOOD DB9 MALE <br /> CONNECTOR AT GAS CONTROLLER �---�� 22 { <br /> 9 ONG_ LAN GABLE PER REGISTER, 700 F001 LENGTH WITH NO CONNEGTOR$. <br /> J% THE RdaK CONNECTORS 4tilll. !1•E iNSYgLLEO BY HE NCR INSrA11.ER. <br /> k; EXISTING D-BOX CABLE 1 f,. AIM <br /> f <br /> p3 ON BACK ROOM WALL WORK STATION Q <br /> TABLE 2O OPT. CASH REGISTER #3 <br /> EXISTING GAS CONTROLLER 0625 CONNECTOR _ D69 iANNECrOR <br /> D -BOX(E PAM ISDN <br /> UNE PRUNE \ _, FIDEL 2O CASH REGISTER 02 ONE BATMAN MONEY ORDER CABLE FOR CHEYEN( E MONEY ORDER <br /> D`S OX(S) PAM <br /> ^ MACHINE CABLE INCLUDES CHEYENNE KIT WHICHI INCLUDES ONE OB9 <br /> SEE NOTES 1,2 & 3 �� r - \ SAFE-�. ' CONNECTOR FOR THE MONEY ORDER MACHINE AND ONE 0025 CONNECTOR <br /> e-NISP HUB ROUTER 1 S � \ 21 IDG REG. d3 iHECA 1_E IIS USED WITH <br /> END WITH n 089 CONN LTOR_ THE BATMAN <br /> _ FOR THE ISP COMPUTER <br /> ONE CONNECTOR IN PUCE; THE BARE END OF <br /> N CABIENN TRENCH / � - X710 CABLE��� 0 PULL THE CABLE AND WILL REQUIRE THE - <br /> GRIND CONTROL CABLE(S) t - } 4 MONEY ORDER CABLE /) //\\ <br /> TO GASOLINE DISPENSERS CAT 5 CABLE RJ45 / 1�,/J SAFE--^ CONNECTOR ro BE PINNED AND INSTALLED. { <br /> DISPENSERS PATCH ` s <br /> h CORDS I - 3/4. 115V IOG CIRCUITTO EACH REGISTER <br /> INC. FUTURE REG. X13 <br /> ai NOTE; 3/4" CONDUIT 15 <br /> \`\� . 21 IDG REG g2 <br /> FUTURE LOTTERY, SAFE CABLES <br /> MONEY ORDER CABLE <br /> 9. EXISTING GAS CONTROLLER (FOLLO I MODEL PAM TSt000) 20 CASH REGISTER p1 HOOD DBa'r HOOD r;DO <br /> WILL REQUIRE ONE OF THE FOLLOWING CHANGES: <br /> FEMALE CONNECTOR .HALE caN^1ECrCR <br /> A. A NEW FIRMWARE CHIP TO BE PLACED TSP END HACKROOM ,� .... .- <br /> IN THE GAS CONTROLLER 19 MONEY ORDER <br /> AN 21 IDG REG, #1 i . -^... QA� t <br /> B. A BOARD ADDITION PLACED 14 3 - 3/4' CONDUIT LAN CABLES pNF' GAS CONrpRt LFR CnDLE <br /> IN THE EXISTING GAS CONTROLLER <br /> OR pR9J C1 NQz <br /> C. ANEW GAS CONTROLLER WITH THE pD25GASOLNE TANK M .1017 LO <br /> NEW CHIP AND BOARD, FEMALE CONNECTOR MONITOR <br /> 2. PETROLEUM SYSTEM CONVERSION WALK-THRU r��� _ <br /> f BACKROOM DRAWN; MSP <br /> FORM WILL BE PERFORMED BY THE ASC u- <br /> 3. INSTALLATION OF THE GAS CONTROLLER CHANGES AND ��/ /y IABFf NTS ENO OF CABLE � ApPR(}1fE,p �-m- <br /> NEW GAS CONTROLLER CHIP, BOARD AND CABLE: WILL NEW STORE RETAIL AUTOMATION wliH NDELIFILE INK AS GTM INyrALLATON or (A8tr BY MALE PINS TO BE CONNECTED Cl <br /> BE BY ASC CERTIFIED SOUTHLAND GAS MAINTENANCE IN iH¢ CABLE, COVER ELECTRICAL CONTRACTOR TO D025 HOOD BY <br /> CONTRACTOR. - CABLE SUPUED BY SOUHLF,NO ELECTRICAL CONTRACTnR <br /> 1 COMPUTER WIRING DIAGRAM PT <br /> ( 5 ) POS GAS , CONTROLLER DIAGRAM NONE E►. SCALE �N� 4 CABLE D TAILS 71F, <br /> _. c.E <br /> e NONE t . 1 , � <br />
The URL can be used to link to this page
Your browser does not support the video tag.