My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DANIELS
>
2440
>
2300 - Underground Storage Tank Program
>
PR0527629
>
INSTALL_2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:41:30 PM
Creation date
11/4/2018 2:26:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2013
RECORD_ID
PR0527629
PE
2351
FACILITY_ID
FA0018721
FACILITY_NAME
Costco Wholesale #1031
STREET_NUMBER
2440
STREET_NAME
DANIELS
STREET_TYPE
ST
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
2440 DANIELS ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DANIELS\2440\PR0527629\INSTALL PLAN 2013.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
restricting delivery of flow to the tank at least 30 minutes before the tank overfills, provided <br /> the restriction occurs when the tank is filled to no more than 95 percent of capacity; and <br /> activate an audible alarm at least five minutes before the tank overfills." <br /> Response: The overfill prevention method is the external audible/visual alarm set at 90% <br /> of the tank capacity. The applications have been revised accordingly and included with this <br /> resubmittal. <br /> 2. Items 35, 36 and 38 on page T-5 of the plans are Bravo brand penetration fittings for <br /> double-walled sumps. The manufacturer's cut sheet provided was for single-walled fittings. <br /> Please provide the double-walled cut sheets for the Bravo penetration fittings. <br /> Response: The correct cut sheets are included with this resubmittal. <br /> VERBAL COMMENTS PROVIDED BY: ARIS CACAPIT, REHS/TELEPHONE: (209)468-3453 <br /> 2680 REYNOLDS RANCH PARKWAY, LODI,CALIFORNIA 95240 <br /> COSTco Loc. No. 10911 OUR JOB No. 14573 <br /> Monitoring Plan: <br /> 1. Page No. 2 of 2, Section VII-line 490-66: Secondary Containment would not need to be <br /> tested every six months because it is under continual 24-hour monitoring. No. 2 does not <br /> need to be checked. <br /> Response: The application has been revised per comments and is included with this <br /> resubmittal. <br /> 2. With the Section X-you put the "Overfill alarm set at 90% for overfill protection." What it <br /> should say 'Audio Visual Alarm for overfill protection" insert audible visual alarm after the <br /> 90%for line 490-71 <br /> Response: The application has been revised per comments and is included with this <br /> resubmittal. <br /> 3. 1 noticed that in the monitoring plan you list the Veeder-Root 323 sensors as the sensor to be <br /> installed. On Page 8 of the Install Application, Section 1, it looks like 208 sensors but the <br /> parts list also lists 323, so maybe the 208 should be switched to 323 <br /> Response: The applications have been revised to identify the use of the 323 sensor, not <br /> the 208. <br /> 4. Alarm Panel: The model according to your monitoring plan - maybe on page 8 (of the Install <br /> Application) we should also put in the model, TLS350R, because that should also match up <br /> with the parts list on the full-size site map. <br /> Response: The Veeder-Root model number has been updated on all applications. <br /> 5. Page T-3 of the Site Map Section C, there is a #51 which refers to, according to the parts list <br /> provided, a fitting for a round sump. However, according to the site plan, that sump is not <br /> round but has a flat side to it. You should check on that <br /> Response: The actual point-of-entry for the product line will occur at the round part of the <br /> existing sump. Only the bottom 24-inches of the existing sumps are flat sided (polysided). <br /> The upper portion of the sump is round. See Elevation View D for point-of-entry of the <br /> product line. <br /> 12919c.039.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.