Laserfiche WebLink
far- Pm <br /> �NIFIED PROGRAM CONSOLIDATED FOR <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN-(Pae I of 2) <br /> 4'w-I <br /> TYPE OF ACTION [011.NEW PLAN E 2.CHANGE OF INFORMATION Ph <br /> (��/��V�1�V�I ^ 190-2 <br /> PLAN TYPE E I.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. HEALTH DEI <br /> PTMENT <br /> LAN <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): _ - <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agenry Use Only) - - <br /> FTJ <br /> BUSINESS NAME(Same as FACILITY NAME)COSTCO WHOLESALE GAS STATION#1031 <br /> BUSINDRESS 2440 DANIEL STREET <br /> 03 CITY MANTECA 04 <br /> ESS SITE AD <br /> If. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance.and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency <br /> specified by the equipment manufacturers' instructions.or annually,whichever is more frequent,and that such work must be performed by qualified personnel. <br /> (23 CCR§2632_2634.2638.26411_____________________________..________-_______.-_______-_______._____.______--_____.______.-______.---___.____________..._-----_--________.__ <br /> MONITORING EQUIPMENT IS SERVICED E I.ANNUALLY ❑ 99.OTHER(Specify): 490-3b <br /> Ill. MONITORING LOCATIONS <br /> ❑I.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN. E2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED. (23 CC'R§2632, <br /> 2634)490-4 <br /> IV.TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S): <br /> ® L CONTINIIOLIS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACES)OR SECONDARY CONTAINMENT 490'5 <br /> VAULT(S)WITH AUDIBLE AND VISUAL ALARMS. (23 CCR§2632,2634) <br /> 490-b <br /> SECONDARY CONTAINMENT IS: ❑ a.URY E b.LIQUID FILLED ❑ c.PRESSURIZED ❑d UNDER VACl1UM <br /> 411 1 490-R <br /> PANEL MANUFACTURER_-VEEDER_ROOT _- - IMODEL#: TLS-350 <br /> __ 490-I0 <br /> LEAK SENSOR MANU FACTURER: VEEDER ROOT 4900 MODEL#(S): 794380-301 <br /> ❑ 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).(23 CCR§2643) 19111 <br /> PANEL MANUFACTURER: <br /> 490-12. MODEL 9: <br /> I---TANK PROBE MANUFACTURER: <br /> 400-14 MODEL4(8): 491-1s <br /> ______________________________________________-______-________.-.-___-.-__-___.______-_-________________-__________-_.._.__ 490-IG <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILYWGHTLY ❑ c.WEEKLY <br /> 17 <br /> [I ..-___________..____d.MONTHLY ❑ e.OTHER(Specify): 090-- <br /> _ <br /> -__________ -________ ________-______---._______ ._______._______-_ ____________.___________..._________________._________.._________--_________.-_________-_______ <br /> _ _ ____ _ <br /> 490-IR <br /> PROGRAMMED TESTS: ❑ a.0.1 g.p.h. ❑ b.0.2 g.p.h. ❑ c.OTFIER(Specify): 490-19 <br /> 490-20 <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION(23 CCR§2646.1): <br /> 490-21 <br /> El 4.WEEKLY MANUAL TANK GAUGING(MTC)(23 CCR§2645). TESTING PERIOD: [Ia.36 HOURS Elb.60 HOURS 490.2, <br /> E] 5.TANK INTEGRITY TESTING(23 CCR§2643.1): 490 3 <br /> 4%21 <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.BIENNIALLY ❑ c.OTHER(Specify): 490-25 <br /> 490-26 <br /> ❑99.OTHER (Specify): 490-21 <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S)(Check all that apply) <br /> 1.CONTINUOUS MONITORING OF PIPE/PIPING SIIMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE AND 4"0'28 <br /> VISUAL ALARMS. (23 CCR§2636)§2636) 00., <br /> SECONDARY CONTAINMENT IS: Ea.DRY Eb.LIQUID FILLED []c.PRESSURIZED ❑d.UNDER VACUUM <br /> _-----------------------------------------------------------________-.__-______.________________________r__-__------_.__----_--------_---------------_---- <br /> PANEL MANUFACTURER:VEEDER ROOT 4B0 30 ago 3 <br /> 1 MODEL#: TLS-350 <br /> ----------------"----------------------------------------------------------------------------------------------------------------------`-------_:_85-080-------------'------------- 490-31 <br /> 49°-3z MODEL#(4) 857080112 <br /> 490-14 <br /> LEAK SENSOR MANUFACTURER: VEEDER ROOT -___t-_--________:_-._..______-.�.______________________. <br /> PIPING LEAK ALARM IRIGG ERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. E a.YES ❑b.NO <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. E a.YES ❑b.NO 90-35 <br /> ❑ 2.MECHANICAL LINE LEAK DETECTOR(MELD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF <br /> _PRODUCT FLOW WHEN A LEAK IS DETECTED(23 CCR_2636)_ 410-3b <br /> MELD MANUFACTURER(S): 490-3] MODEL#(S): 490-39 <br /> ® 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS (23 CCR§2636) 490-19 <br /> ___-_______-______.__-_.-.-..____...._____....______________________-_____________________________-___________________--49041 <br /> ELLD MANUFACTURER(S)VEEDER ROOT 190-4o <br /> MODEL#(s),_-PLED(8484) - ----------_----- <br /> ___-_..-------------_ _ _________________ _________._____-________._________.________________ 490-42 <br /> PROGRAMMED IN LINE LEAK TEST: ❑ 1.MINIMUM MONTHLY 0.2 g.p.h. ❑ 2.MINIMUM ANNUAL 0.1 g.p.h. <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. E a.YES El b.NO 49043 <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. E a.YES ❑b.NO 490-d4 <br /> ❑ 4.PIPE INTEGRITY TESTING 49°45 <br /> TEST FREQUENCY ❑ a.ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHER(Specify) 490-4649041 <br /> ❑ 5.VISUAL PIPE MONITORING. 490-48 <br /> FREQUENCY ❑ a.DAILY ❑ b.WEEKLY ❑C.MIN.MONTHLY&EACH TIME SYSTEM OPERATED- 490.49 <br /> Allowed for monitoring cfunburied emerLency generatoT fuel iping only per HSC 425281.5(6(3 <br /> F16.SUCTION PIPING MEETS EXEMPTION CRITERIA 123 CCR§2636(x)(3)(. 490-50 <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM <br /> 490-51 490-52 <br /> ❑ 99.OTHER(Specify) 490-51 <br /> Belshire Environmental Services, Inc. <br />