BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DANIELS
>
2440
>
2300 - Underground Storage Tank Program
>
PR0527629
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2023 10:45:22 AM
Creation date
11/4/2018 2:28:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0527629
PE
2351
FACILITY_ID
FA0018721
FACILITY_NAME
Costco Wholesale #1031
STREET_NUMBER
2440
STREET_NAME
DANIELS
STREET_TYPE
ST
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
2440 DANIELS ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DANIELS\2440\PR0527629\BILLING 2013 - 2014.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NIFIED PROGRAM CONSOLIDATED FORM• <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN (Page 2 of2) JUN - <br /> VI UNDER DISPENSER CONTAINMENT(UDC)MONITORING�� „��_,7CU�X <br /> 1. UDC MONITORING IS PERFORMED USING THE FOLLOWING METHOD N� vI�E® LCONTINUOUS ELECTRONIC MONITORING ❑ 2.FLOAT AND CHAIN ASSEMBLY ❑ 3.ELECTRONIC STAND-At, E <br /> -❑ 4_NO DISPENSERS___�99.0111ER(Specify):_________-____.__________________________._____a90=ss.1_________________._________-____.___.______-- 49o-s6. <br /> PANEL MANUFACTURER:VE_EDE_R ROOT _MODEL#:TLS-350 <br /> a9as] a9ass <br /> ___..LEAK SENSOR MANUFACTURER:RER:VEE <br /> EEDER ROOT__________.____.________.____________ _________.__________________________.______.___— <br /> MooEL w(s):794380-323 <br /> a.YES ❑h.NO ago-59 <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS ® aYES [I h.NO 4D0-W <br /> UDC .LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN 490-fit <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES a.YES El b.NO 49-61 <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER. 400 63 <br /> 2.UDC CONSTRUCTION IS [ILSINGLE-WALLED ®2.DOUBLE-WALLED -- <br /> IFDOUBLE WALLED: <br /> __UDC INTERSTITIAL SPACE IS MONITORED BY__® L-LIQUID_- ❑_2_PRESSURE �3,VACUUM__------------_--------_---_._______________________. <br /> A LEAK WITHIN THF.SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS ®a.YES ❑b.NO <br /> 90fi46 <br /> VII.PERIODIC SYSTEM TESTING <br /> ❑ I. ELD TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCED 49-65. <br /> LFAK DETECTION(ELD)MUST BE PERFORMED. PERIODIC ELD 1S PERFORMED EVERY 36 MONTHS AS REQUIRED.(23 CCR§2644.1)_-_ <br /> ___ .. _ __.. _.-- --❑ _______ 490.66 2.SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS, _ __ -_____- _-________ <br /> __ 490-67 <br /> ®3.SPILL BUCKETS ARE TESTED ANNUALLY. <br /> VIII.RECORDKEEPING <br /> The following monitoring/maintenance records are kept for this facility: <br /> ®Alarm logs 490-68a ❑Visual Inspection Records 490-68b ❑Tank integrity,testing results 490-6so <br /> 11SIR testing results(and supporting documentation records). 490-68d ❑ Tank gauging results(and supporting documentation records). 490-6ae <br /> ❑ATG Testing results(and supporting documentation records).490-68f ❑ Corrosion Protection 60-day logs 490-688 <br /> ®Equipment maintenance and calibration records. 49a6sh <br /> IX.TRAINING <br /> ®Personnel with UST monitoring responsibilities are familiar with all of the following documents relevant to theirjob duties. 490-69a <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY?(Check all that apply) <br /> M THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required)4go-69b <br /> ® OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required)490-69c <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 490-69d <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW 49-69e <br /> ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br /> STATISTICAL INVENTORY RECONCILIATION”490-69f <br /> ❑ SWRCB PUBLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS"490-691 <br /> ❑ OTHER(Specify):M69h.M69i <br /> ®This facility has a"Designated UST Operator"who has passed the California UST System Operator Exam administered by the International Code Council(ICC). <br /> The"Designated UST Operator'will train facility employees in the proper operation and maintenance of the UST systems annually,and within 30 days of hire.This <br /> training will include,but is not limited to,the following: <br /> Y Operation of the UST systems in a manner consistent with the facility's best management practices <br /> The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan <br /> The facility employee's role with regard to spills and overfills as specified in the UST Response Plan <br /> 'r Names of contact persons)for emergencies and monitoring alarms.490-70 <br /> X. COMMENTS/ADDITIONAL INFORMATION <br /> Provide additional comments here or indicate how many pages with additional information on specific monitoring procedures are attached to this plan.490-71 <br /> ( PAGE—SENSOR SUPPLEMENTAL FORM ATTACHED <br /> XI. PERSONNEL RESPONSIBILITIES <br /> The UST Owner/Operator is responsible for ensuring that: 1)the daily/routine UST monitoring activities and maintenance of UST leak detec;theo"erloperator <br /> pment covered by <br /> this plan occurs,2)all conditions that indicate a possible release are investigated,and 3)all monitoring records are maintained properly. <br /> The following pemon(s)are responsible for performing the monitoring and equipment maintenance. <br /> NAME DENNIS BOCK 490-72 TITLE COMPLIANCE MANAGER 490as <br /> NAME TIM HURLOCKER TITLE DIRECTOR OF GASOLINE OPERA <br /> The Designated Operator shall perform a monthly visual inspection of the facility, provide a report to the owner/operator, and inform of any <br /> conditions that need follow-upaction. <br /> XH.OWNER/OPERATOR SIGNATURE <br /> CERTIFICATION: 1 certify that the information provided herein is true and accurate to the best of my knowledge. 490 n <br /> APPLICANT SIGNATURE 490-76 DATE: /�v <br /> I ,l(yr G7/L(r / 2 <br /> REPRESENTIN ❑I Tank Owner10 ergror [12.Facilit Owner/O erabr_®r Authorized R resen ive of wner 490)9 <br /> 490"79 APPLICANT TITLE: <br /> APPLICANT NAME(print): <br /> DENNIS BOCK COMPLIANCE MANAGER <br /> Belshire Environmental Services, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.