My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DANIELS
>
2440
>
2300 - Underground Storage Tank Program
>
PR0527629
>
COMPLIANCE INFO_2013 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2023 2:07:49 PM
Creation date
11/4/2018 2:28:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2016
RECORD_ID
PR0527629
PE
2351
FACILITY_ID
FA0018721
FACILITY_NAME
Costco Wholesale #1031
STREET_NUMBER
2440
STREET_NAME
DANIELS
STREET_TYPE
ST
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
2440 DANIELS ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DANIELS\2440\PR0527629\COMPLIANCE INFO 2013 - 2016.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
461
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 466-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Costco Wholesale #1031 <br />Facility Address: <br />2440 Daniels ST, Manteca <br />Date: <br />August 18, 2016 <br />SUMMARY OF VIOLATIONS <br />(CLASS 1. mA3311, or MINOR- Nonce to comply) <br />Item # <br />Remarks <br />209 <br />CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to document all the alarms from the attached alarm history on the September 2016 <br />designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br />missing alarms include: <br />S11 (87A Vent Vacuum) Communication alarm - 8/16/16 <br />During the monthly inspection, the designated operator shall review the alarm history for the previous month, check <br />that each alar was documented and responded to appropriately, and attach a copy of the alarm history with <br />documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br />monthly inspections at this facility are including all of the required information on the reports. <br />This is a minor violation. <br />304 <br />HSC 25290.1(d) Monitoring system not maintained to detect entry into secondary containment (after Jul 2004). <br />According to the maintenance records on site, the L9 (87B Fill) sensor went into sensor out alarm on 10/29/15. The <br />technician who responded to the alarm noted that the sensor would not go into a fuel alarm, even when flipped upside <br />down. A service request application was submitted on 11/2/15. A permit approval letter was issued dated 11/19/15. <br />The maintenance records on site indicate the sensor was not replaced until 1/20/16, on the day of functionality <br />verification testing with an EHD inspector. The 87B fill sensor was incapable of detecting a leak from 10/29/15 until <br />1/20/16. The continuous monitoring system shall be maintained to detect the entry of the liquid or vapor phase of the <br />hazardous substance stored in the primary containment into the secondary containment and to detect water intrusion <br />into the secondary containment. The sensor has been replaced and retested. Ensure that all sensors are maintained <br />to detect the entry of the liquid or vapor phase of the hazardous substance stored in the primary containment into the <br />secondary containment and to detect water intrusion into the secondary containment at all times. <br />This is a Class II violation. <br />306 <br />CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br />The brine sensors monitoring the annular spaces of all eight UDCs were found not located at the top of the UDCs to <br />detect a leak at the earliest opportunity. The brine level in all of the UDCs was low and the sensors were located too <br />low to have detected the drop in brine level. In some UDCs, the brine level was not high enough to reach the site <br />gauge. Monitoring equipment shall be maintained to be able to detect a leak at the earliest possible opportunity. The <br />brine was topped off and all sensors were relocated to the top of the UDC annular level by the service technician. <br />Ensure that all monitoring equipment is maintained to detect a leak at the earliest opportunity. <br />This was corrected on site. <br />This is a Class II violation. <br />Page 4 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.